NFPA diamond top red square is for what hazard?
Fire
Structural firefighting protective clothing is often referred to as _____
Bunker Gear
The _____ is an electronic device that emits a loud, audible signal when a firefighter becomes trapped or injured.
Personal Alert Safety System (PASS)
What class fire is a flammable liquid?
Class B
A _____ is formed by reversing the direction of the rope to form a U bend without crossing the rope so it has two parallel ends.
Bonus name all
Bight
Loop, Round Turn
What is the "B" in CBRN
Biological
Firefighters should be able to don and activate an SCBA in _____.
60 seconds
Location
Unit
Names
Air
Resources needed
What is the most fire resistive type of construction?
Type I
The stored-pressure water-type fire extinguisher with a 2-A rating carries _____ of water.
2.5 Gallons
A backup team should never be more than _____ from being fully dressed and ready for action.
A minute or so
An SCBA has a(n) _____, which allows the air from the air cylinder to enter the face piece without passing through the regulator.
Regulator Purge/Bypass Valve
A buddy breather is also referred to as a(n) _____.
EBSS (Emergency Breathing Support System)
A _____ is an explosion caused by the introduction of oxygen into a compartment where superheated gases and contents are hot enough for ignition but do not have sufficient oxygen to combust.
Name all 3 parts of a rope
Standing part, running end, working end
The term for what would be best for containing a large volume of organic solvents that are lighter than water and moving down a trench.
Underflow Dam
According to NIST at what temperature does a SCBA facepiece lens start to become soft?
300 F
Name this breathing technique: the firefighter takes a short breath, holds it, takes a second short breath (without exhaling in between breaths), and then relaxes with a long exhale.
Skip Breathing
Name the 4 stages of fire growth
Incipient, Growth, Fully developed, Decay
Once the initial size-up report has been given, the IC needs to _____
Perform a 360 walk-around
_____ is a chemical action involving the molecular breakdown of a protective clothing material or equipment due to contact with a chemical.
Degradation
The _____ is the federal agency that specifies the design, testing, and certification requirements for respiratory protection.
National Institute for Occupational Safety and Health
(NIOSH)
Explain what a UAC is
Universal Air Connection.
Used by RIT crews to supply air to a downed FF
NFPA _____ is the Standard on Types of Building Construction.
220
All incidents handled by the fire service have three priorities in the following order: _____.
Life Safety, Incident Stabilization, Property Conservation