Alpha
Bravo
Charlie
Delta
Echo
100

Doors that open away from the firefighter usually lead to ___________?

Living Spaces

100

Proximity gear's outer shell works by  ______ heat created from aircraft and petroleum-based fires.

Reflecting

100

This type of knot is used to tie the ends of webbing together.

Water Knot

100

How much does water weigh per pound? 

8.33 lb

100

What does the acronym PASS stand for? 

• Pull

• Aim

• Squeeze

• Sweep

200

Doors that open towards the firefighter usually lead to _________?

Doors that open toward you usually lead into service areas such as utility rooms or can be indicative of an elevation change such as steps that lead to a basement or attic.

200

What is the definition of a fire load? 

The total amount of combustible materials stored or used in a building, including combustible building contents and furnishings not built in to the building.

200

When using a portable ladder for roof access, one should extend the ladder ______ rungs above the roofline?

5 Rungs

200

In these types of windows, a coating is applied to each layer of glass in the unit. Each unit can be either double glazed or triple glazed, meaning that it has two or three vertical panels. Each panel is separated by an air gap that is normally filled with some type of inert gas such as argon or krypton.

Low-E Glass

200

A _______ is a structural component using one or more triangular units to attain stability.

Truss

300

What is a live load? 

Aa nonfixed (sometimes moving ) variable load that is added to the structure, including people, materials, and other transportable items.

300

Fire flows for hand lines operating in commercial structures should be a minimum of:_______gpm

250

300

This type of search is the bread and butter of all search operations in the fire service. This technique lends itself well for use in private dwellings, apartments, and relatively small operational areas.

Perimeter Search

300

A wet chemical extinguisher is specifically designed for what classification of fire?

Class K

300

As a ladder is raised, what component of the ladder supports and interlocks with a corresponding section.

Channel Guide

400

A simple beam is supported by how many points? 

400

A cotton-jacketed hose must be ______ before reloading on to the apparatus.

Dried

400

What are the 4 sources of heat? 

Mechanical, Electrical, Nuclear, and Chemical

400

Which layer of turnout gear protects the firefighter from convective and conductive heat?

Thermal Layer

400

A ______ will turn black if exposed to temperatures greater than 300° F.

Heat Sensor Label

500

What is the definition of a cantilever beam? 

A cantilever beam is supported at one end only (e.g., a balcony, which is supported by attachment to the structure at one end).

500

The firefighter should be cognizant of how many floors they may have ascended for two reasons. One is to keep one's orientation. What is the other?

Assist with a rapid intervention

500

When the upper thermal layer reaches a temperature of about 500–600°C (about 900–1100°F) you could experience the start of ______?

Flashover

500

This type of extinguisher is designed as an alternative to halon in areas where contamination must be kept to a minimum without the expense of halon substitutes. It causes little damage to most electronic circuits and is the safest agent available for use on humans (such as in operating rooms)

 Water Mist

500

What type of respiratory protection for nonfire applications, when used in fire department operations, includes some type of escape cylinder that is carried by the user in case of failure of the air supply line?

Supplied-air respirator

M
e
n
u