General Knowledge
General Knowledge 2
General Knowledge 3
Building Construction
NFPA Standards
100

Hives, pallor, bronchospasm, wheezing, upper airway obstruction, and hypotension; indicates?

What is an Allergic Reaction

100

Sever Crushing chest pain, or substernal pressure, radiating to left arm/or jaw, shortness of breath, diaphoresis, pallor, dysrhythmias, hypertension or hypotension indicates possibility of this. 

What is a Acute Myocardial Infarction?

100

When directions are given to a rescue boat during a water rescue incident the directions (right and left) are referred to as this.

What is river right and river left?

100

This type of collapse involves void spaces on outside walls and failure of center supports in a floor system. 


What is V-Shaped Collapse?


100
Standard for firefighter professional qualifications.
What is NFPA 1001
200

Located at 8070 Tartan Fields Drive.

What is The Club at Tartan Fields?

200

Length of blitz lines carried on E343?


What is 250ft? 


200

The maximum heat that can be produced if all the combustibles in an area burn.


What is fire load?


200

This construction type has non-combustible walls, a wood roof and can include tilt-slab or reinforced masonry construction.

What is Type 3 (Ordinary Construction)?

200
Standard on protective ensemble for structure firefighting.
What is NFPA 1971
300

Total gallons of water on scene if Q341 and E343 are on scene?

What is 1500 gallons?

300

Length of supply line on E343.

What is 1500 ft.? 

300

These three products of combustion( carbon dioxide, carbon monoxide, and hydrogen cyanide) are considered...

What is hazardous?

300

Construction type that both UL and NIST have studied and found that components will fail within minutes of direct flame impingement.

What is Type 5 - Wood Framed Construction?

300

Standard for Firefighter Health and Safety

What is NFPA 1500?

400

Device in our cache of equipment that allows changing from lowering to hauling system without changing out hardware.

What is an MPD

400

This type of knot makes a non-directional loop.

What is a butterfly knot?

400

Route that air/oxygen takes when it heads in to feed the fire and the route that fire, smoke or heat heads for, to leave the building.

What is the Flow Path?

400

Type of collapse where one or more walls have failed, and the other end of the floor is still attached to the other bearing wall. Voids are sporadic throughout the debris.  The most dangerous type of collapse to operate in, and adequate shoring must be in place before operations can commence.

What is Cantilever Collapse?

400

Standard for the Organization and Deployment of Fire Suppression Operations, Emergency Medical Operations, and Special Operations to the Public by Career Fire Departments.

What is NFPA 1710?

500

These two ratios are the mechanical advantages built into to the AZTEC Pulley system. 

What is 4:1 and 5:1

500

This device is the preferred rope grab device when preforming a water based rescue.

What is an ascender?

500

Cracks or separation in walls, ceilings, floors, or roof, loose bricks or stones falling from the building, and deteriorated mortar between masonry are indications of this imminent danger. 

What is building collapse?

500

Maximum length of a header used in building a single T-Shore.

What is 3ft?

500

Standard on Life Safety Rope and Equipment for Emergency Services.

What is NFPA 1983?

M