Firestop Materials
Alpha-Numeric
Fire Behavior
Firestop Terminology
Ratings & definitions
Union Knowledge
100

This Firestop material comes in square or rectangular shapes and is used on the outside of electrical boxes.

What are putty pads?

100

This is the 1st letter used in a Firestop system that covers both Floors & walls.

What is C?

100
Three components of the fire triangle.
What is Heat, Fuel, Oxygen.
100

This term is used when any material is able to catch fire and burn easily.

What is combustable?

100

This rating is expressed in hours on the "Non Fire Side" of the fire rated system that does not exceed 325 degrees above ambient temperature.

What is a T-rating?

100

This person currently holds the position of Local 7 President!

Who is Monty Anderson

200

These Firestop components are commonly used to "tuck in" to wall penetrations and can expand 10%-60% when a fire occurs

What are wrap strips?

200

The numeric code range that Firestopping cables would be found.

What is 3000-3999?

200

Fire class of energized electrical equipment.

What is Class C.

200

This is the act of restoring the hourly fire endurance rating back to the manufacturers specifications.

What is Firestopping?

200

This rating, expressed in hours, indicates a specific time a product has been tested withstanding passage of fire and a successful hose stream test.

What is an F-rating?

200

This is the year that Local 7 signed their Charter with the International.

When was 1912

300

This type of coating or sealant swells up when heated

What is Intumescent?

300

The numeric code range that Firestopping  Bus ducts and other miscellaneous electrical penetrations would be found.

What is 6000-6999

300

When a fire is in contained in a compartment, the smoke will tend to develop into layers according to temperature.

What is Thermal Layering.

300

This specific testing is currently on the top of the priority list for smoke rated construction.

What is an Air-leakage test?

300

This rating, for air leakage & smoke, is measured in cubic Ft per minute 2 ambient temperature & 400 degrees.

What is an L-rating?

300

This section of the CBA is where you you would find language regarding "hours of wok"

What is Article Vl

400

Very common fire resistive wall covering. Made of gypsum, starch and water then sandwiched between two layers of special paper.

What is Drywall/Sheetrock?

400

The numeric code range that Firestopping mixed multiple penetrations would be found.

What is 8000-8999?

400

Rapid transition between growth and fully developed fire stage. Conditions within compartment change very rapidly from partial to full fire involvement.

What is Flashover.

400

This is the ability of a material to return to it's original shape.

What is Elasticity?

400

This is the practice of dividing space into fire resistant areas.

What is Compartmentation?

400

This amount of Related Supplemental Instruction hours is required by the state of Washington, to successfully complete 1yr of the apprenticeship.

What is 160 hours

500

This type of material burns away at a controlled rate.

What is Ablative?

500

This code prescribes the pressure and duration of the hose stream test.

What is UL-1479?

500

This term is used when a fire growth is limited by the air supply within a compartment.

What is Ventilation Controlled.

500

This term is a failure from grease, dust or shrinkage characterized by rupture within the sealant.

What is Cohesive failure?

500

The penetrant enters only 1 side of the fire barrier and does not exit.

What is a membrane penetration? 

500

This is where the fundamental principles of local 7, which determine the responsibilities of our officers and members, can be found.

What is the Local 7 const. & bylaws.

M
e
n
u