Circuit vent
Wet vent
Combination waste and vent
General venting
General knowledge
Fixture layout
Traps
100

How many fixtures are allowed per vent on a circuit vent

8

100

Name three fixtures that can be wet vented

Water closet,  lavatory,  bath tub or shower, bidet, emergency floor drain 

100

What is the maximum slope for a combination waste and vent

1/2" per foot

100

What must a vent pitch to

A drain

100

What is the weight of water

8.33 pounds per gallon

100

How far off the back wall is a standard toilet rough in

12 inches off finished wall

100

What is the only legal trap in our code

P-trap

200

Individual or __________ vented fixtures may be tied into the circuit vent

Common

200

How many bathrooms on the same floor level can be wet vented with one vent

2

200

How far can a fixture be from a vent in a combination waste and vent system 

Unlimited 

200

What is the minimum size penetration for a vent through a roof

3 inch

200

What is the minimum area of a shower pan

900 square inches

200

How far off the center of a flush valve is the water supply roughed in

4 3/4"

200

What is the drum trap exception 

Solids interceptor 

300

Whats the maximum slope of a circuit vent

1" per foot

300

Each wet vented fixture drain shall connect ______ to the horizontal wet vent

A. Upstream

B. Downstream 

C. Independently 

D. Horizontally 

C. Independently 

300

When running a combination waste and vent, what is the only vertical pipe allowed. 

The riser to the fixture drain

300

What is the minimum height of a vent where the roof is being used as a sun deck

7 feet

300

How do you find the volume of a roof with a parrapit wall

Length x width x height

300

How far off the side wall is a handicapped toilet roughed in

16-18 inches

300

What is the maximum vertical distance from fixture outlet to trap weir 

24 inches 

400

A relief vent is required when tieing into a stack that receives the discharge of what

The discharge of soil or waste from upper horizontal branches

400

The dry vent connection for a vertical wet vent shall be an individual or common vent for the most ______ fixture drain

A. Upstream         B. Downstream 

C. Any position     D. Used

A. Upstream

400

What is the maximum vertical distance for the vertical offset to the fixture drain

8 feet

400

What is the minimum vent size

1 1/4"

400

What is pi

3.14

400

What is the rim height of a handicap toilet

17 inches

400

Name three illegal traps

Crown vented traps, bell traps, s-traps, drum traps, traps with moving parts, traps with interior partitions

500

How many toilets draining into a circuit vent are required before a relief vent is needed

4

500

Any additional fixtures shall discharge ______ from the horizontal wet vent

Downstream 

500

What 4 fixtures can be combination waste and vented

Floor drains, sinks, lavatories and drinking fountains 

500

What is the trap to vent distance for a 1 1/4" trap

5 feet

500

What is the constant for a 45° offset

 Offset x 1.414

500

What is the rim height of a handicapped lavatory

34 inches

500

What is the minimum and maximum liquid depth of a trap

2-4 inches

600

The fixture drains must connect to the horizontal branch of the circuit vent in what position 

Each fixture drain shall connect horizontally

600

How many DFUs can go into an 1 1/2 " wet vent

1

600

The combination waste and vent shall be provided with a dry vent at any point, or shall be connected to a horizontal drain that serves _______

Any legally vented fixture

600

A vent must be half the size of the drain it serves unless the total developed length exceeds ______, in which case it must be increased be one pipe size

40 feet

600

A ten foot riser of pipe will have how much pressure at the bottom

4.33 psi

600

What is the rim height of a standard non-handicap urinal

24 inches 

600

In what location would floor drain not be trapped

Parking garages

M