This shall be done before entering a wet fuel tank. The 2 approved methods given are Air___ and Fluid___.
What is purging 1-1-3 Para 5.5.2.5
This number is associated with the name of this category.
What is the -20? 1C-130J-2-28JG-20-1
THIS NUMBER IS ASSOCIATED WITH FUELS IN THE WUC.
WHAT IS 46000? 1C-130J-06
I DONT MARK THE SPOT, BUT I TELL YOU THAT AN ACFT IS CONSIDERED UNSAFE, UNSERVICEABLE, OR NOT AIR WORTHY.
WHAT IS A RED X? 00-20-1 PARA 4.2.1
NOT EXACTLY SPECIFIC BUT USE THIS TASK FOR COMPONENTS ALL OVER THE ACFT.
WHAT IS REMOVE TYPICAL FUEL SYSTEM CHECK VALVE? 1C-130J-2-28JG-00-1 28-00-30 TSK 4-1-1
This ___ covers general procedures associated with preparations for open fuel tank/cell repair.
What is the General Checklist for Fuel Tank/Cell Entries? 1-1-3 Para 5.4.2
These valves allow fuel into the tanks and are operated electrically and hydro-mechanically.
What are Fuel Level Control Valves? 1C-130J-2-28GS-00-1 PARA 3.2.5
THIS CODE, CONSISTING OF AN ALPHABET OR A LETTER, TELLS YOU WHAT WORK WAS DONE TO AN ACFT.
WHAT IS AN ACTION TAKEN CODE? 1C-130J-06 PARA 2.4
I AM THE STANDARD DATE FORMAT USED FOR ALL FORMS.
WHAT IS YYYYMMDD 4 DIGIT YEAR, 2 DIGIT MONTH, 2 DIGIT DAY. 00-20-1 PARA 3.5
I GET REMOVED FIRST IF YOU WANT TO TAKE OFF THIS DOOR.
WHAT IS THE MAGNETIC SIGHT GAUGE? 1C-130J-2-28JG-00-1 28-00-11 TSK 2-2-2
This table is not for eating. Instead it shows you how bad a leak is and where it is.
What is Table 4-1 Leak Classification Table - Integral Fuel Tanks? 1-1-3 Table 4-1
THIS ACAWS MESSAGE CAUTIONS OF A 1000LB DISCREPANCY IN YOUR LEFT EXTERNAL TANK.
WHAT IS A "L EXT TK HEAVY"? 1C-130J-2-28GS-00-1 TABLE 3-1
DESPITE ITS NAME, THIS 3 DIGIT NUMERIC CODE IS NOT USED FOR FUEL TANKS.
WHAT IS HM CODE 197 - FUEL LEAKAGE? 1C-130J-06 HOW MAL CODES.
AN ADDITIONAL INSPECTION OR VERIFICATION STEP AT A CRITICAL POINT IN THE INSTALLATION, ASSEMBLY OR REASSEMBLY OF A SYSTEM, SUBSYSTEM OR COMPONENT.
WHAT IS AN IN PROCESS INSPECTION? 00-20-1 2.4.20
THIS OTBD MT #2 PROBE FACES THIS DIRECTION ON INSTALLATION.
WHAT IS AFT? 1C-130J-2-28JG-40-1 28-41-10 TSK 2-1-3
Not Kai Cenat, this device shall be connected to any cap, plug, cover plate, or test door affecting the vent system.
What is a yellow "REMOVE BEFORE REFUELING/DEFUELING" streamer? 1-1-3 Para 2.7.6.4.2
ONE OF THE MAIN FUNCTIONS OF THE H20 REMOVAL SYSTEMS ASIDE FROM: REMOVING H20, PROVING A POSITIVE SUPPLY OF FUEL TO THE BOOST PUMPS, AND REMOVING FUEL FROM THE VENT TANKS.
WHAT IS "MAXIMIZING FUEL CAPABILITY"? 1C-130J-2-28GS-00-1 PARA 3.6
THIS CODE IS USED FOR COMPONENTS IN THE DRY BAYS, NOT THE FUEL TANKS.
WHAT IS WUC 115BR - BRACE? 1C-130J-06 WORK UNIT CODES
YOU ARE GOING TO USE ME ALOT TO CLEAR MESSED UP JOBS.
WHAT IS PARA 4.6.1.5.4 DISCREPANCY ENTERED IN ERROR? 00-20-1
DAILY DOUBLE
PROPER INSTALLATION MAY INVOLVE BLADES AN GRAVITY.
WHAT IS INSTALL FOAM BAFFLES? 1C-130J-2-28JG-10-1 28-11-30 TSK 2-1-4
You aint gotta be pretty to perform this kind of "hot work" with these measurements.
What equals 90 PPM and 1.5% LEL? 1-1-3 Table 5-1
A RARE TIME WHEN THE OUTBOARD INBOARD 2ND SOLENOID IS OFF WHILE THE INBOARD 1ST SOLENOID IS ON.
WHAT IS THE 4TH PART OF THE FLCV TEST? 1C-130J-2-28GS-00-1 PARA 3.3.3.1
THIS FORM WILL BE SUBMITTED WHENEVER A CODE 99 IS USED.
WHAT IS AN AFTO FORM 22? 1C-130J-06
THIS FORM IS USED TO DOCUMENT MX STATUS AND SERVICING STATUS.
WHAT IS THE 781H? 00-20-1 5.13
IM NON-TANK ENTRY, BUT I STILL HAVE AN EXPLOSION WARNING.
WHAT IS REMOVE REFUEL SURGE SUPPRESSOR? 1C-130J-2-28JG-20-1 28-21-30 TSK 2-4-1