Gas Heat #1
Gas Heat #2
Pot Luck #1
Oil Heat #1
Pot Luck #2
100

The most common furnace configurations are

downflow, upflow, horizontal, and multipoise

100

. In an intermittent pilot (IP) ignition system

the pilot is lit electronically each time there is a call for heat

100

Which of the following would cause a problem with the flame rectification circuit

A poor ground wire connection

100

The voltage provided by a solid-state igniter typically ranges from

14,000 V to 20,000 V

100

Which of the following is true regarding preventive maintenance on oil-fired heating equipment?

Oil-fired heating systems typically require more preventive maintenance than other types of heating appliances

200

A tool, which measures in inches of water column, that can be used to test gas pressure is a

digital manometer

200

The component on which the spuds and burners are mounted to is the

manifold

200

Incomplete combustion produces which of the following toxic substances?

Soot

200

Which of the following statements is true regarding the cad cell?

The resistance of a cad cell decreases when it senses light

200

A control’s response to a specific number of unsuccessful trials for ignition is a(n)

lockout

300

The pressure at the manifold for natural gas is typically

3.5 in. WC

300

The component that contains and separates the flue gas from the medium being heated is the

heat exchanger

300

The principal of flame rectification is based on the fact that

a flame can conduct electricity

300

Condensing furnaces are vented with piping made from

PVC  (i.e. Plastic )

300

In a two-stage furnace, the typical manifold pressure in low-fire is

1.75 in. WC

400

The three things needed for combustion are

fuel, air, and heat

400

The component that consists of several thermocouples wired in series to increase voltage output is the

thermopile

400

Before fuel oil can burn it must be

atomized

400

Which of the following is true regarding condensing furnaces?

Condensing furnaces have multiple heat exchangers.

400

The horizontal run of the flue pipe on a gas-burning furnace should be sloped

¼ in. rise per foot

500

The pressure at the manifold for LP is typically

10.5 to 11 in. WC.

500

To test the flame rectification circuit, a digital multimeter should be placed

in series with the flame sensor to test microamps

500

The motor on an oil burner is responsible for turning the

burner fan and the fuel pump

500

Which of the following is the correct formula for calculating net stack temperature?

Net Stack Temperature = Flue Temperature - Indoor Ambient Air Temperature

500

A thermopile typically generates

500 to 750 DC millivolts