money money money
tis the season for heating
die hard is not a xmas movie
sometimes its just a filter
5 more weeks for some of you
100

how much combustion air is required to burn and properly vent 1 cubic foot of natural gas?

15 cubic foot

100

the typical manifold pressure for liquified petroleum (LP) gas appliance should be

10-11 inch w.c.

100

what reading should a good thermocoupler produce on a DC meter?

30 millivolts

100

a technician starts a standing pilot furnace and notices when the blower is energized the flames "roll out". the technician correctly suspects

a cracked heat exchanger

100

when venting  a category I furance, it is sometimes necessary to increase the vent pipe size. the proper location to adapt to the larger vent is

3 feet above the furnace connection

200

what is this component called

transformer

200

the efficiency rating of a gas burning appliance is determined using the

afue or annual fuel utilization efficeincy 

200

liquified petroleum (LP) gases are

propane and butane

200

the proper metjhod for testing flame rectification is

placing the meter in series with the flame sensor to test the DC microamps

200

you are installing 1/2 inch and 3/4 inch black iron pipe to a natural gas furnace. when threading, what is the approximate number of threads to cut?

7-10 threads

300

the purpose of a flue baffle is to

increase heat exchange

300

which conditions would cause the temperature limit safety switch to shut of the burners

fan motor failure

300

when the burners of a furnace are ignited, the blower motor operation is delayed to 

allow the heat exchanger to warm up first

300

to react to a change in temperature, the fan/limit switch in a standing pilot furnace uses a helical shaft made of

bi-metal

300

the proper name for the tool used to cut the threads of steel pipe is a 

die

400

the ignition temperature of natural gas is

900-10000 degrees

400

the cut off plate is a component of the 

blower housing

400

which of the following test instruments ca be used to check the gas pressure of a furnace?

manometer

400

type b vent pipe constructed with an inner pipe and an outer pipe. the inner pipe is made of

aluminum

400

what would likely be the result of an oversized furnace?

the furnace would operate at a low temperature split

500

air that is mixed with natural ga in the burner is called

primary air

500

a "spud" or burner orifice

controls manifold pressure

500

the igniter in a hot surface ignition furnace does not energize after the inducer draft motor is energized. the proper action for the technician would be to?

check for voltage through the pressure switch

500

what type of draft is used to move flue gas through the heat exchanger and into the venting system in a modern gas-fired furnace

mechanical

500

the normal voltage for a hot surface igniter is

120 volts

M