The Proximal and Distal OD (French Size) of the Phenom 17 Catheter.
What is 2.2 & 1.8?
The Proximal and Distal OD (French Size) of the Phenom 17 Catheter.
What is 2.2 & 1.8?
The Proximal French Size of the Phenom 45 Catheter
What is 4.7 French?
The Proximal French Size of the Phenom 45 Catheter
What is 4.7 French?
The number of randomized trials showing aspiration's superiority over TPA in treating Large Vessel Occlusions.
What is Zero?
The percentage of Physicians who rated Phenom 17 as equal to or better than their current Microcather
What is 91%?
The percentage of Physicians who rated Phenom 17 as equal to or better than their current Microcather
What is 91%?
Aside from Pipeline cases, this is the most common support application for Phenom 45.
What is Distal AVM's and Fistula's?
Aside from Pipeline cases, this is the most common support application for Phenom 45.
What is Distal AVM's and Fistula's?
The Complication rates when comparing Premier Data to Surpass.
What is 10 VS 2% in our favor?
The available tip shapes of Phenom 17
What is S, 45, 90, J?
The available tip shapes of Phenom 17
What is S, 45, 90, J?
The OD of Phenom 45 AND will it fit through a 6F Envoy or Benchmark.
What is .062 AND Yes (.070 / .071?)
The OD of Phenom 45 AND will it fit through a 6F Envoy or Benchmark.
What is .062 AND Yes (.070 / .071?)
The Scale for Measuring Viscosity of Onyx (18 & 34.)
What is the Centistoke Scale?
The primary advantage over SL-10, Microcather market leader
What is best in class distal support, better stability translating to less microcatheter kickout?
The primary advantage over SL-10, Microcather market leader
What is best in class distal support, better stability translating to less microcatheter kickout?
Phenom 45 presents this clinical advantage to Sofia.
What is better distal support?
Phenom 45 presents this clinical advantage to Sofia.
What is better distal support?
The two primary takeaways of the 5 Landmark Stroke Trials from 2015.
The three performance zones of the Phenom 17 catheter
What is the coiled distal zone (allows device resheathability,) the coiled / braided mid-zone (smooth transition force proximal to distal,) and proximal braided zone (pushability and low proximal profile?)
The three performance zones of the Phenom 17 catheter
What is the coiled distal zone (allows device resheathability,) the coiled / braided mid-zone (smooth transition force proximal to distal,) and proximal braided zone (pushability and low proximal profile?)
Phenom 45 Presents this advantage to competitive flow diversion products.
What is Digs the Moat, Fills it with Gasoline and Lights the Match? (Also acceptable, blocks them out?)
Phenom 45 Presents this advantage to competitive flow diversion products.
What is Digs the Moat, Fills it with Gasoline and Lights the Match? (Also acceptable, blocks them out?)
The OD of an Axium Prime Frame 8x20 Coil.
What is .0135?