Preferred current for GTAW welding mild steel
DCEN
Recommended post flow time for welding at 200amps
20 secs
1 sec for every 10 amps
Yellow band on one end of tungsten
1% thoriated
This component ensures electrical contact between the torch body and the collet
Collet body
This metal requires back purging using GTAW
Power source used for GTAW
Constant Current
L/min and CFH
Red bad on one end of tungsten
2% thoriated
These are known as
Back caps
used for control of porosity on mild steel
deoxidized filler rods
Type of current that promotes greater control over heat input
Pulsed
Preferred shielding gas for GTAW heavier gauge aluminum
Helium
White band on one end of tungsten
EWZr-8/Zirconium
Component known as
Collet or Electrode Collet
Rule of thumb for estimating GTAW stickout
1 to 2 electrode diameters or no more than the diameter of the cup
Which half cycle is reduced using GTAW process on AC
DCEP
Shielding gas preferred for light gauge material
Argon
Gold band on one end of tungsten
EWLa-1.5
1.5% Lanthanum oxide/Lanthanated
Component known as
Collet body
Amperage limit for air cooled GTAW torches
up to 200A
DCEN with HF is used to provide
Non touch arc start
DAILY DOUBLE===Excessive gas flow causes what GTAW defect typically and what is the correct flow rate for GTAW
Undercut
15 to 25 CFH
Most commonly used electrode for welding aluminum and magnesium alloys (Green, with balled tip)
EWP
Pure Tungsten
Component know as
Gas lens
What number do we call in case of an emergency on campus (not 911), also what building number and room are we in for practical work?
6152(security) and Building 130, room 110. Call 911 for fire and ambulance if needed of course.