100

The price of our Standard troubleshooting & diagnostic

Bonus: It includes _______

What is $366

Bonus: This covers the troubleshooting & Minor repair of an electrical problem on ONE CIRCUIT ONLY. This task includes an unlimited amount of time to determine the problem and the replacement of any one small part to restore power (outlet, switch, or standard breaker). In the event new wiring has to be installed an additional flat rate task will be required. 

100

Distance between two ground rods

Code requires 6'

Sparky Standard is 8'

100

*DAILY DOUBLE*

Name 2 components used to identify the grounding system for an inspector

What are:

1. 2" PVC Coupling

2. Flag

100

Provide a Feature of our smoke detectors

Dual-sensing (Photoelectric and Ionization)

10yr sealed battery backup


100

Integrity of electrical equipment and connections?

Code article

110.12B

200

Standard Hot Tub circuit up to 30'

Bonus: It includes ________

& does not include _______

What is $1347

Includes nothing additional

Trenching, permits, disconnect, and gfci breaker are all at an additional fee

200

Minimum conductor size for 100a residential service

What is #4 AWG copper

200

What size copper feeder is required for a 200a commercial service?

3/0 copper

200

Benefits to a home redevice 

All new TR/WR devices

some specialty devices are included

"Shepards hook" connections not "backstabbed"

all connections done by certified electricians


200

Table for wire ampacity?

310.16

300

Main panel surge protector

Bonus: Describe some FAB's

What is $826

Feature: Audible alarm, LED indicator, lowest clamping voltage available,

Advantage: up to 30% additional lifespan from appliances

Benefits: $50,000 connected equipment coverage

300

The smallest wire size that can be phased

#4 AWG

300

When is duct seal required?

When a conduit penetrates between two different temperatures.

300

What surge protectors come in a standard surge package 

Panel 

Secondary

Coax or Cat 5

300

The temperature rating associated with the ampacity of a conductor shall be selected and coordinated so as not to exceed the lowest temperature rating of any connected termination, conductor, or device. Conductors with temperature ratings higher than specified for terminations shall be permitted to be used for ampacity adjustments, corrections, or both.

110.14(C)

400

Single pole specialty breaker (gfci or afci)

Bonus: Do or do not Discount for more than 1

What is $301

Bonus: Arc fault or ground faults DO NOT get a bulk discount price unless we provided the panel

400

Minimum running KW size for a portable gen. install

(Inlet with main interlock)

10KW running watts or larger

400

Solve the following:

1. The maximum wattage for a 120v 20a circuit

2.  The amps for a 9600w AHU 

voltage x amperage = watts

1. 2400w maximum

watts/voltage = amps

2. 40a

400

Benefits of Cutler-Hammer products

All copper busbar

Lifetime manufacturers warranty on panel and breakers

Trip-indicate window on breakers


400

Table showing standard size circuit breakers?

240.6(A)

500

50 device Arc-Fault redevice

Bonus: Application for providing

What is $5119

Bonus: We could provide this as an alternative to rewiring when there is only a hot and neutral wire 

500

Minimum wire size for an A/C with the following specs:



What is #10 AWG

why?

500

How many #10 conductors can you fit in 3/4 sch 40 PVC?

9

500

Advantage or benefits to using Mister Sparky

Most answers accepted

500

•Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or those permitted as part of the design for listed equipment, shall be closed to afford protection substantially equivalent to the wall of the equipment. Where metallic plugs or plates are used with nonmetallic enclosures, they shall be recessed at least ¼” from the outer surface of the enclosure.

110.12(A)