Parts
Refrigeration Cycle Components
Heat Pump Modes
Heat Pump Types
Voltages
100

Changes the direction of refrigerant flow

What is the Reversing Valve?

100

Start of the refrigeration cycle

What is the Compressor?

100

Nothing energized

What is the Off Mode?

100

Heat is absorbed from Air into the refrigerant and then rejected from the refrigerant into Air

What is Air-Source Heat Pumps?

100

R to C when the Thermostat is NOT making a call for ANY mode

What is 24 Volts?

200

Initiates and Terminates 

What is the Defrost Control Board?

200

Directs refrigerant to the Outdoor Coil during Cool Mode

What is the Reversing Valve?

200

Outdoor Coil is HP-HT, Indoor Coil is LP-LT, Outdoor Metering Device Bypassed

What is the Cooling Mode?

200

Heat is absorbed from Water into the refrigerant and rejected into the Air

What is Water-Source Heat Pumps?

200

Reversing Valve in the Heat Mode with a goodman unit

0 Volts

300

Energized to add supplemental heat

What are Electric Heat Strips?

300

Bypassed during the Heat Mode

What is the Indoor Metering Device?

300

Indoor Coil is HP-HT, Outdoor Coil is LP-LT, Indoor Metering Device Bypassed

What is the Heat Mode?

300

Water-Source Heat Pump that absorbs it's heat from the ground

What is Geothermal Heat Pumps?

300

Comp=240 Volts, OFM=240 Volts, RVS=24 Volts, IFM=240 Volts, Heat Strips=0 Volts

What is Cooling Mode?

400

Prevents liquid refrigerant from entering the Compressor

What is the Accumulator?

400

Condenser Coil during the Heat Mode

What is the Indoor Coil?

400

Outdoor Coil is HP-HT, Indoor Coil is LP-LT, Outdoor Fan De-energized, Heat Strips Energized

What is Defrost Mode?

400

Water-Source Heat Pump where the water comes from a well

What is Water-to-Air Open-Loop Heat Pump?

400

Comp=240 Volts, OFM=0 Volts, RVS=24 Volts, IFM=240 Volts, Heat Strips=240 Volts, Y - C=24 Volts, O - C=24 Volts, W2 - C=24 Volts

What is Defrost Mode?

500

Separates liquid refrigerant from oil

What is the Crankcase Heater?

500

Outdoor coil in heat mode

What is the Evaporator?

500

Outdoor unit & Compressor locked out, W2 becomes W1 energizing the Electric Heat Strips

What is Emergency Heat Mode?

500

Heat Pump system that uses two water coils and no Air Coils

What is a Water-to-Water Heat Pump?

500

Comp=0 Volts, OFM=0 Volts, RVS=0 Volts, IFM=240 Volts, Heat Strips=240 Volts, R - C=24 Volts, Y - C= 0 Volts, O - C=0 Volts, R - W2=0 Volts

What is Emergency Heat Mode?