100

what is the most common complaint from a customer changing from gas heat to a heat pump

cold air at high velocities out of the registers

100

which component is responsible for changing the direction of the flow of refrigerat

reversing valve

100

during the defrost cycle, the outdoor fan is usually

turned of

100

on a split system heat pump, a "no heat" service call, you turn the thermostat to the fan on/ cont position and the indoor fan operates. the action verifies that

the transformer is functioning

100

during the defrost cycle, the system switches to the ______ mode

cooling

200

what a heat pump is operating in the heat mode, the suction line at the compressor will feel

cold and sweaty

200

some heat pump systems use a ______ as a metering device

fixed orfice

200

systems rated at 7.5 toms and higher, which use the thermostatic expansion valve at each coil will also have

a bypass line with check valve

200

on most air-air heat pumps

airflow must be reduced over the indoor coil during the heat mode

200

during the heating mode, the refrigerant in the indoor coil is under

high pressure

300

the use of a scroll type compressor on a heat pump can eliminate the need for a

suction line accumulator

300

the slide valve and piston in the reversing valve is actuated by pressure directed through the 

solenoid and pilot valve

300

refrigerant flow through the compressor

is always the same regardless of operating mode

300

heat pump system, operating at 45 degrees ambient, may be ______ efficient than electric resistance heat

3 to 4 times more

300

what 3 things happen on most air-to-air heat pumps during defrost?

the reversing valve must switch to cooling mode, the outdoor fan shuts off and auxiliary heat is energized

400

a heat pump operates satisfactory in the cooling mode, but not the heat mode. this could be caused by 

a stuck check valve or clogged txv screen


400

during the heating cycle, the outdoor coil becomes

an evaporator 

400

because of the possibility of liquid floodback, a heat pump that uses a reciprocating compressor should be equipped with a

suction accumulator

400

since electric resistance heat provides 1 watt of useable heat for each watt of energy purchased, electric heat has a COP of

1 to 1 

400

the preferred method to perform adjustments to the refrigerant charge in a heat pump system is in the _____ mode

cooling

500

it is not always a good idea to immediately connect a standard gauge manifold set and hoses to a heat pump when a problem is suspected because

the charge is critical, sometimes  1/2 ounce refrigerant

500

during the cooling cycle, the indoor coil becomes

an evaporator

500

a scroll type compressor

is less susceptible to damage from liquid floodback

500

as outside ambient air temperature decreases, a heat pumps COP

decreases

500

a customer complains that their heat pump system blows cool air periodically during the heat mode. this could be caused by

a faulty defrost relay ( does not energize the aux heat during the defrost cycle

600

when a heat pump is in the heating mode, what can cause frost accumulation on the outdoor coil when the ambient temperature is 45 degrees

the outdoor coil is colder than the ambient air

600

the indoor fan on a heat pump system operates

anytime there is a call for heating and cooling

600

the defrost cycle can be initiated by

time and temperature

600

the defrost cycle can be terminated by

time/temperature

600

liquid line filter/driers that are used on heat pump systems

must be a bi-flow design if used without check valves