AFCI
GFCI
Grounding Bonding
Electrical Code and Theory
OHM’S Law
100

AFCI stands for this

What is Arc Fault Circuit Interrupter

100

GFCI stands for this

What is Ground fault circuit interrupter

100

Ground rods must be at least this many feet apart

What is 6

100

This article provides definitions in the NEC

What is article 100

100

The letter I signifies this 

What is current

200

Combination style Arc Fault breakers protect against these types of arcs

what are series and parallel

200

A GFCI receptacle works by monitoring the current between these two conductors

What is the grounded and ungrounded conductors

200

This article in the NEC is all about grounding and bonding

What is article 250

200

When referencing a continuous load, this is the amount of time it must be running for

What is 3 hours

200

This unit of power is the result of volts multiplied by amps

What is a watt

300

There are multiple class action lawsuits against multiple manufacturers for this type of tripping that occurs.  

What is nuisance tripping

300

A standard household GFCI will trip if the current is imbalanced by this range of milliamps

What is 4 to 6

300

A concrete encased electrode is the proper NEC name for this slang term

What is a Ufer Ground

300

This range of voltage drop is recommended for feeders or branch circuits in the NEC

What is 3 to 5 %

300

Ohms law defines the relationship between these three quantities 

What is voltage current and resistance

400

This is the NEC section specifically for AFCI protection

What is 210.12

400

This NEC section lists the required areas for GFCI protection

What is 210.8

400

This is the term for what connects the grounded circuit conductor to the equipment grounding conductor in a main panel

What is a main bonding jumper

400

In a 3 phase delta connected system the high leg must be marked with this color and landed on this phase

What is orange and B phase

400

Ohm’s law was name after this German mathematician and physicist.

Who is Georg Ohm

500

When replacing a sub panel AFCI protection is not required if the circuits are not moved more than this many feet.


What is 6

500

According to the NEC all appliances in a kitchen rated 125-250 volts and this ampere rating must be GFCI protected.  

What is 50

500

The UFER ground was named after this consultant for the US Army

Who is Herbert Ufer

500

In a parallel circuit ____ is the same and in a series circuit ____ is the same

What is voltage and current

500

A 120 volt, 2400 watt appliance produces how many amps

What is 20

M
e
n
u