Sanitary and Industrial Holding Tank
Above and In-Ground Holding Tanks
Holding Tank Management Plans
Rules and Regulations
100

The number of days of storage that a Sewage Holding Tank must have.

10 days

100

This is the range of Volumes for approvable Holding Tanks

1000 gal minimum to 7500 gal maximum

100

This PTI Form is submitted in order to approve a HTMP

Form A – C3

100

This individual has the right to essentially permit whatever he or she desires.

The Director

200

The maximum amount of daily sanitary waste that may be added to an industrial holding tank.

25 gpd

200

Below grade holding tanks must meet this level of loading to ensure pressure from above does not damage the tank.

H-20 Loading

200

HTMPs expire after this many years

5 years

200

The Chapter of OAC that Holding Tank Rules fall under.

OAC Chapter 3745-42-11

300

The sign Adjacent to an industrial Holding tank shall label the tank as the follows:

Non-Hazardous Industrial Waste

300

Automatically filled holding tanks must have these two things.

A liquid level device connected to an autodialer 

A light alarm

300
What are the 2 contracts needed in order to approve a HTMP?

Facility and Hauler

Hauler and Disposal Location

300

Recreational vehicle park, camp, combined park-camp, and/or a temporary park-camp fall under this regulation.

ORC 6111.46

400

The Agency does not permit Holding tanks if Sanitary Sewers are available in this amount of time.

12 months

400

The ER number that must be posted near all holding tanks.

(1-800-282-9378)

400

The amount of the Fee for a new HTMP when submitted alongside a PTI.

$0

400

This is the effective date of OAC Chapter 3745-42-11

2018-02-23

M
e
n
u