TJOIN
TMETER
TMETER/OFF
TLEAK
TCORR
100

A wrenching technique used to create leverage and stability.

What is back-up piping/back-up wrenching/back-holding.

100

A device that reduces standby pressure to the appliance control unit and it is required for all 2psi system.

What is an inline or downstream regulator.

100

The two devices used when leaving a red tagged meter or turned off for non-pay.

What is a Barrel Lock & Blind Disk. 

100

An instrument that is to be turned on and use when approaching customer's home, at the meter set and inside the customer's home.  


(Calibrate within 30 days)

What is a CGI.

100

Common compound used on meter sets to protect pipes from corrosions.

What is Paint.

200

1.5-3.0 Turns after finger tighten.

What is a turning ratio for a 3/4 pipe.

200

A performance use to confirm that the voltage pen is working properly. 

What is a Live Dead Live test.

200

According to FCS-PR-1040: 

If the amount or above is detected, you are to STOP WORK IMMEDIATELY.

What is 12 volts AC on a meter set.

200

1100 to 1200 Degrees in a combustion.

What is an Ignition Temperature 

200

The condition that does not constitute atmospheric corrosion (AC), but it is the first sign or the beginning of an (AC).

What is surface oxidation/General corrosion.

300

A lubricant used on meter swivels and unions to prevent seizing.

What is Lithium Grease. 

300

Make the scene safe.

Report the situation.

Make corrective repair if qualified.

What are the appropriate reactions to task specific AOC's. 

300

An instrument that is to be on and zeroed out prior to installing into the test port and to be calibrated within a year.

What are Pressure gauges.

300

Three methods used to check for leaks.

What is Soaping, CGI and Flow test.

300

Clean the surface,

Spray with glass plus cleaner,

Wipe and a perform additional ACI,

Let dry and apply an approved paint. 

What are steps to cure minimal corrosion. 

400

The primary locations to apply pipe dope on a threaded pipe.

What is the first 4 threads.

400

Ignition source within 3ft of the regulator.

Window within 18 inches center of the regulator.

Mechanical air intake within 10ft of the regulator.

What is an improper clearance.

400

The primary source of information that is to be verified prior to starting work on meter exchange/turn off.

What is a Meter number.

400

Equal to 20% LEL.

What is 1% gas.

400

Occurs on above ground steal surface in a thin wet film created by humidity and impurities. 

What is Atmospheric Corrosion.

500

The amount of pipe dope to be applied on the first 4 threads.

What is manufacture recommended application. 

500

An inspection preformed on all exposed areas from the outlet swivel to the appliances. 

What is a customer piping inspection.

500

A mandatory action to be taken prior to Installing, Removing or Replacing a regulator.

What is a Lockout-Tagout (LOTO)

500

When detected:

15 PPM require a red tag.

70 PPM require evacuation.

What is CO, Carbin monoxide.

500

An authorization that allows an unqualified person to perform work alongside a qualified person within range and AKA 1-1 ratio.

What is span-of-control. 