Humidification
Heat Pumps
Furnace Components
Safety & Maintenance
Heat Exchangers
100

The three types of humidifiers offered at Schaal / Greens

What are Bypass, Fan-Powered, and Steam humidifiers?

100
The key component which switches to roles of your indoor and outdoor coils

What is a reversing valve?

100

Converts energy from flame into DC signals. 

What is a flame sensor? 

100

This must be done to the flame sensor every maintenance to ensure good flame sense. 

What is cleaning the flame sensor?

100

The combustion byproduct the heat exchanger keeps separated from the breathable air

What is carbon monoxide?

200

A control device for the humidifier

What is a humidistat?

200

Component responsible for de-icing the outdoor coil in lower temperatures

What is a Defrost Control Board / Defrost Timer?

200

Creates a negative pressure. 

What is an inducer motor? 

200

A furnace must be tagged and locked out if this component is found cracked or damaged. 

What is a heat exchanger? 

200

This component pre-treats the air in 90% efficiency systems

What is a secondary heat exchanger?

300

This type of water used in portable humidifiers can plug up filters with mineral deposits

What is tap water?

300

This heat pump uses consistent ground temperatures for year round comfort

What is a geothermal heat pump?

300

If the label on this component reads L140-30F, it means the component fails at 140 and closes when it drops 30 degrees. 

What is a high temperature limit switch? 

300

You will get pressure switch error codes if these are not clear of blockages, debris, and snow. 

What are (exhaust / intake) terminations?

300

They type of heat transfer when air absorbs heat from the heat exchanger

What is conduction?

400

The wire terminal that the humidistat uses to control the blower independent of the heating cycle 

What is the Gf terminal? 

400

When the heat pump's energy efficiency begins to fall short of the back up / auxiliary heat

What is the balance point?

400

Varies the burner input rate from 40% full to 100%, often in 1% increments. 

What is a modulating gas valve?

400
The recommended amount of CFM for an 80k, 90% efficiency furnace

What is 1200 CFM?

400

The style of heat exchanger in which two plates of metal are pressed together

What are clam-shell style heat exchangers?

500

A measurement of water particles in the air

What are grains of water?

500

A component used to bypass a metering device in a heat pump

What is a check valve?

500

Where the gas valve, manifold, and pilot assembly are generally housed. 

What is the vestibule? 

500

Never change the size of this component unless directed by the manufacturer. Can result in incomplete combustion and unstable operation. 

What is a gas manifold orifice? 

500

When soot and scorched metal are present in the heat exchanger as a result of too much gas pressure.

What is overfired? 

M
e
n
u