Oil furnace 1
Oil furnace 2
Parts of oil furnace
Random 1.
Random2.
100

The nozzle prepares the fuel oil for combustion by doing what to the fuel?

Atomizing it

100

What does (gph) stand for?

Gallons per hour

100

If there is an after drip, this part is installed to prevent it.

Solenoid

100

This part generates the voltage for ignition.

Step up transformer

100

What are the insulators on electrodes made of?

Ceramic

200

An oil pump pressure of 100 psig and a nozzle marked at 1.00 will deliver what amount of fuel per hour?

1 gallon

200

What are the three basic spray patterns?

Hollow, semi solid and solid

200

What takes high voltage down to nozzle for ignition?

Electrodes

200

When a nozzle gets dirty and makes firing a problem, what should you do?

Replace the nozzle

200

What all does the burner motor operate?

Oil pump, air for combustion

300

What type of fuel oil is most common in households?

Number 2

300

What is sometimes installed in the flue that will will shut down the furnace if it doesnt detect heat?

Stack switch or stack relay

300

What part, tells the furnace in what orders it will come on?

Primary control

300

On a boiler system, what does the thermostat open in order to heat up a room?

zone valve

300

What is the difference between a one pipe and a two pipe system?

One pipe needs bled, two pipe does not

400

Where does the fuel of an oil furnace ignite into called?

Combustion chamber

400

When the blower turns on, where is it getting its heat from?

Heat exchanger

400

What can be added to a one pipe system that will make it function like a two pipe system?

Deaerator

400

What happens after time in an oil furnace if there is excessive smoke?

Create soot build up.

400

What detects flame on a gas furnace

Flame sensor

500

What's the difference between interrupted ignition, and intermittent ignition?

Interrupted employs a spark at the beginning then stops to where the intermittent is continuous spark.

500

This part detects flame.

CAD Cell

500

With under ground steel tanks, what are installed to help non corrosion?

dielectric bushings and sacrificial anodes

500

Besides clogging, what else could make problems for proper ignition at the nozzle?

Worn electrodes or spread to far apart

500

when getting a new nozzle. what does it mean when you see   .85    80A

.85 gph  angle 80 degrees

M
e
n
u