The Fundamentals
Circle of Cool
The Cool Juice
Under Pressure
Coiled Again!
100

A ton of refrigeration

What is 12,000 BTUs / hour? 

100

This causes a pressure differential in the system, which allows refrigerant to flow.

What is a compressor?

100

Identified by their grey tanks and yellow shoulders

What is a recovery tank? 

100

If there is an internal failure, it cannot be repaired. 

What is Hermetic Compressor? 

100
In cooling, the Heat Absorber

What is an evaporator coil? 

200

Heat added to a vapor after a change of state...

What is superheat? 

200

This component is responsible for a pressure drop so the evaporator coil can more easily boil off refrigerant

What is a metering device?

200

Will tell you how much liquid you have in your outdoor coil...

What is subcool? 

200

A capillary tube is an example of this type of metering device

What is a fixed metering device? 

200

The most likely reason your unit is tripping on a high pressure limit code. 

What is a plugged condenser coil? (low outdoor airflow)

300

Increases and decreases with the pressure...

What is Saturation Temperature? (would also accept temperature)

300

How refrigerant leaves a TXV or Piston

What is a low-pressure, low-temperature liquid-vapor mix

300

The most accurate way to charge refrigerant

What is charging by weight? 
300

Reads your suction line temp and adjusts the opening in your TXV. 

What is a sensing bulb? 

300

The first thing to check when you have ice over your evaporator coil

What is filter / static pressure / airflow? 

400

The recommended CFM setting for the following: 

What is 1200 CFM? 

400

The line where you are most likely to find high-pressure, high-temperature vapor

What is the discharge line? 

400

The measurements needed to determine target superheat

What are indoor wetbulb and condenser dry bulb? 

400

The compressor winding that should read the largest resistance

What is Start to Run? 

400

Used to make the coils change jobs

What is a reversing valve? 

500

14°C, but in America

What is 57.2°F?

500

This remains constant in the evaporator until all refrigerant has changed state. 

What is temperature?

500

This refrigerant is NOT compatible with copper tubing. 

What is Ammonia? 

500

Indicated by power going to the compressor, but no change in refrigerant pressures

What is broken scroll plate / crank shaft?

500

A type of coil developed to eliminate standard round copper or aluminum tubing. 

What are microchannel coils? 

M