HVAC Basics
Electrical Hazards
Finding the Problem
Swamp Coolers
Firefighter Safety
100

This indoor component's main job is to move and condition the air inside the building.

What is an air handler. 

100

This is the primary electrical hazard firefighters need to worry about when approaching HVAC equipment.

What is electrical shock/electrocution.

100

Smoke or a burning smell coming from the HVAC vents may point firefighters toward this indoor component.

What is the indoor air handler/blower motor.

100

This process cools warm outside air by passing it through water-saturated pads?

What is evaporation. 

100
Rooftop HVAC units create this additional firefighting hazard when operating on the roof?

What is a trip/fall hazard. 

200

This outdoor component contains the compressor and outdoor fan.

What is a condenser/condensing unit. 

200

This HVAC component can store electrical energy even after the power has been disconnected.

What is a capacitor.

200

This component can overheat and cause smoke or a burning smell when its bearings fail or it locks up.

What is a blower motor. 

200

This component moves cooled air from the swamp cooler into the building?

What is the blower fan.

200

If gas is present, firefighters should locate and close this.

What is the gas shutoff valve.

300

In a split HVAC system, the indoor air handler and outdoor condenser are connected by these.

What are refrigerant lines.

300

Simply pulling the HVAC disconnect isn't enough; firefighters should do this to confirm the power is actually off.

What is test/verify with a meter.

300

These electric heating elements can collect dust over the summer and produce a burning smell when first turned on in winter.

What are heat strips. 

300

Unlike refrigerated air conditioning, a swamp cooler generally requires this to allow incoming air to flow through and exit the structure?

What is an open window, door, or exhaust vent. 

300

After pulling the electrical disconnect, firefighters should use this to verify there is no voltage.

What is a voltage meter/electrical tester. Hot Stick

400

A system that has its major components packaged together in one large unit is commonly called this type of unit.

What is a package/rooftop unit.

400

Someone improperly wiring around the normal disconnect and sending power directly to the equipment is known as doing this.

What is jumping/bypassing the power.

400

In larger commercial HVAC systems, this rubber component can slip, overheat, and produce a burning-rubber smell.

What is a belt. 

400

This device continuously circulates water from the reservoir to the cooling pads?

What is the water pump. 

400

Complete this rule: "Test, don't ______."

What is assume. 

500

This type of HVAC system uses electricity rather than natural gas to provide heating.

What is a heat pump.

500

When checking an HVAC unit for voltage, firefighters should avoid becoming this.

What is the path to ground.

500

Firefighters can use this piece of equipment to locate unusually hot HVAC components without touching them.

What is a TIC.

500

Swamp coolers are most effective in climates with this type of weather condition?

What is low humidity or hot, dry climates. 

500

If the disconnect has been pulled but the meter still detects voltage, firefighters should assume this until the electrical situation is properly addressed.

What is it is still energized and still powered.