Systems
Controlled Devices
Ancillary Equipment
SCADA
Safety
100

What does the acronym DEC stand for in reference to a DEC unit?

Direct Evaporative Cooling

100

What values do the AFMS report back to SCADA?

Airflow, Supply Air Temperature

100

Did the Canadian Wildfires impact our VESDA systems when we had bad air quality? 

Yes (the VESDAs were tripped)

100

What minimum speed % does Thermo leave Supply Fans in for DEC units when not working on them/performing tests?

30%

100

Do you need a ladder to work on top of the Doghouse?

Yes

200

What does the acronym AHU stand for in reference to an AHU unit?

Air Handling Unit 

200

How many wires do our temperature transmitters have originating from the BMS panels? 

2

200

What does the Acronym S.O.A.P. stand for?

Static Outside Air Probe

200

What is the process on SCADA called that is used to change multiple values, change all operating devices at once, or clear all alerts at once?

Global Commander

200

What does the acronym VESDA stand for?

Very Early Smoke Detection Apparatus

300

When looking at Data Halls in a building, how many AHU's would we have total between DH A,B,C & D?

48

300

How many ECH valves are used/controlled in one Data Hall?

48

300

For the Outside Air Dampers in a data hall, how many unique control signals are sent from the panel per AHU?

2

300

What color/level alert is shown when HPS is tripped?

Red/Level 1

300

Summarize why there are smaller doors on main doors leading into a data hall?

Pressure can result in hazardous scenarios with the door impacting into people.

400

In Bluebeam, How many unique selectable BMS packages are related to HVAC (Excluding MISC)?

3 (DH, MDF, Packaged AHU)

400

Which unique Packaged AHU unit uses ONLY 3 AHU's?

BDF

400

What are the two types of fan control modules from outside vendors that are used on the fans throughout the building?"

VFDs and ECMs

400

What is the name of the button on SCADA you would press to control all Supply Fans at once?

SA Fan Control

400

This piece of PPE is commonly used when ramping fans up while being in the same room as the fans.

Ear buds/Hearing protector/etc...

500

Name the type of air that is supplied after running Outside Air through an AHU.

Mixed Air

500

How many Room Differential Pressure sensors are used in each data hall?

4

500

Name a company that is a vendor/builder of the dampers we have in our buildings.

Novenco/Greenheck

500

While working on SCADA in Data Hall B, what is the name of the tab you would use to monitor everything on the ground level?

B1G

500

What OSHA standard covers protection against the effects of noise exposure and excessive sound levels? 

OSHA Standard 1910.95

M
e
n
u