Dead loads for wall above grade shall not exceed ___ pounds per square foot for interior light frame wood walls.
10 PSI R301.2.2.2.1 (3)
Duct heaters located within _____ of a heat pump or air conditioner shall be listed and labeled for such installations
4' M1407.3
The maximum duct temperature for plastic ducts shall not be greater than ________
150 degrees F M1601.1.2
Exhaust ducts shall be supported at intervals not to exceed _________ and shall be secured in place.
12 feet M1502.4.2
What undersea animal is a known predator of moose
Orcas , Moose can dive up to 20' underwater to eat seaweed
Vent Piping shall not be smaller than _____ Pipe
1 ¼ inch pipe. M2203.4
A duct shall extend from the furnace supply outlet to not less than ______ below the combustible framing
6" M1601.5.3
fuel input rate M1304.1
Oil-burning appliances shall be vented with________
Type L vent. Table M1804.1
What president
was buried with his head on the Constitution
Andrew Jackson
Appliances having an ignition source shall be elevated such that the source of ignition is not less than ___ inches above the floor in garages
18 M1307.3
Carbon monoxide alarms shall be provided in dwelling units where either it contains a fuel-fired appliance or has an ______ with an opening that communicates with the dwelling unit
attached garage R315.2.1
Unvented room heaters shall not have an input rating in excess of__________
40,000 Btuh G2445.3
Auxiliary drain pans shall have a minimum depth
1.5 inches. M1411.3.1 (1)
what president had the shortest term
William henry Harrison 31 Days
To obtain a permit you must, ________ the work to be covered by the permit for which application is made.
identify and describe R105.3
The equivalent length of an 8-inch radius smooth 90-degree elbow is _____ long.
1' 7" Table M1502.4.5.1
Vent piping serving relief vents and combination relief and breather vents shall be _________________ to the outdoors and shall serve only a single device vent.
run independently G2421.3.1
Whole-house mechanical ventilation system shall be provided with ______ that enable manual override.
controls M1507
What is the only insect able to turn its head
Prey mantis
A device used for reducing air temperature by the process of evaporating water into an air stream is
Evaporative Cooler Definitions
Studs in a nonbearing partition shall be permitted to be notched to a depth not to exceed ____ of a single stud width.
40%
Where a sediment trap is not incorporated as part of the appliance, a sediment trap shall be _______________ of the appliance shutoff valve as close to the inlet of the appliance as practical. G2419.4
installed downstream G2419.4
Penetrations shall be protected by an approved penetration firestop system installed as tested in accordance with ASTM E 814 or_______
UL 1479. R302.4.1.2