Tech Time
Trouble Bubble
Three Letters
Judgement
Churp
100

What evacuation procedure removes moisture by pulling a vacuum, breaking it with nitrogen, and repeating the process three times?

Triple evacuation

100

What refrigerant issue commonly causes low suction pressure and high superheat?

Undercharge

100

What does EPA stand for?

Environmental Protection Agency

100

What federal law phased down the production and import of HFC refrigerants in the United States?

AIM Act

100

What animal has the same number of neck bones as a human despite having a much longer neck?

Giraffe

200

What tool measures vacuum levels in microns during evacuation?

Micron gauge

200

What refrigerant issue commonly causes high head pressure and poor condenser airflow?

Dirty condenser coil

200

What does ODP stand for in refrigerant regulations?

Ozone Depletion Potential

200

What ASHRAE standard covers the safe design, construction, and operation of refrigeration systems?

ASHRAE 15

200

What planet rains diamonds according to scientists?

Neptune

300

What procedure confirms a system has no refrigerant leaks before charging?

Pressure test

300

What metering device issue commonly causes a starving evaporator and high superheat?

Restricted TXV

300

What refrigerant oil is commonly used with R-410A systems?

POE oil

300

What UL standard addresses safety requirements for HVAC and refrigeration equipment using refrigerants?

UL 60335-2-40

300

What animal can regrow an entire limb after losing it?

Axolotl

400

What gas should be used to safely pressure test and break a vacuum in refrigeration systems?

Nitrogen

400

What refrigerant issue commonly causes high suction pressure and low superheat?

Overcharge

400

What does HCFC stand for?

Hydrochlorofluorocarbon

400

What EPA program evaluates and approves refrigerants based on environmental and safety impacts?

SNAP (Significant New Alternatives Policy)

400

What fast-food restaurant once sold spaghetti?

McDonald’s

500

What service procedure removes air and moisture from a refrigeration system before refrigerant charging?

Evacuation

500

What airflow problem commonly causes an evaporator coil to freeze solid?

Low airflow

500

What certification allows a technician to work on Type 1, 2, and 3 appliances?

Universal certification

500

What ASHRAE standard classifies refrigerants by toxicity and flammability such as A1 and A2L?

ASHRAE 34

500

What planet in our solar system spins sideways compared to the others?

Uranus

M