Indoor Air Quality
Airflow & Design
Troubleshooting
ACE Process
Misc
100

Why is airflow critical for UV effectiveness

What is :

All Contaminants must pass by the lamp to be treated

100

How Many CFM are required Per Ton when sizing residential duct systems?


What is : 

400 CFM / Ton

100

A frozen coil is most commonly caused by these two issues.

What are :

low airflow or low refrigerant

100

"ACE" Stands for?

What is :

Awesome Customer Experience 

100

What must be worn before entering every customer’s home?

What are : 

shoe covers

200

Why do customers still smell odors after UV install sometimes

What is :

The source is still present or insufficient oxidation/contact time

200

This measurement determines how hard the blower is working against the duct system.

What is :

 static pressure

200

Float switch keeps tripping after clearing drain. What’s the real problem

What is :

Double trap, Improper drain pitch or recurring Zooglea buildup

200

Presenting three options to the customer is commonly referred to as this.

What is: 

Good / Better / Best?

200

All Technicians must contact this department before closing out their last call.

What is:

 dispatch

300

Airborne particles can be as small as this measurement.

What is :

0.3 microns

300

Changing the amount of ductwork in a home will require these 2 things 

What is :

30% or more, and add returns to existing bedrooms 

300

Thermostat satisfied but house still feels humid

What is :

Poor Duct design & poor dehumidification or oversized system

300

This is the reason we run ACE calls, beyond just fixing equipment

What is :

To deliver a 5-star experience and create long-term customers (membership + future opportunities)

300

This must happen after every single call to ensure accuracy and set up the next job for success.

What is :

Debriefing with the office

400

Why can a “better  or High MERV Pleated filter"  actually make a system worse

What is :

Increased static pressure reducing airflow

400

A system with high static pressure and low airflow will typically result in this system condition

What is reduced capacity, Excess condensation, and potential coil freezing.

400

What’s the real reason airflow issues are commonly misdiagnosed as refrigerant problems

What are :

Similar symptoms such as (low capacity, poor cooling)

400

When a customer is highly engaged and asking questions, this is how the tech and HCA should operate.

What is :

Split up, with the HCA engaging the customer while the tech continues diagnostics

400

This is the biggest reason techs lose sales / opportunities

What is :

Failure to communicate value

500

A system has correct charge, clean coils, new IAQ upgrades, and still underperforms. Static pressure is high, humidity is elevated, and airflow is inconsistent.

What is :

 poor duct design and airflow restriction affecting total system performance

500

Size the branch duct size for the following mixing box with (2) 8" , (3) 4" , (1) 5" and (1) 9" flex ducts @ .05" WC

What is :

14" Flex for 700 CFM

500

A system has correct refrigerant charge, new equipment, and still performs poorly. What is the true root cause?

What is :

Duct system restriction or improper design

500

This cultural element keeps ACE momentum strong throughout the day and reinforces wins.

What is :

GroupMe chat / real-time communication celebrating wins and updates

500

An HVAC job totaling over this dollar amount requires this   

What is :

$15,000  & a NOC 