Refrigeration Basics
Electrical
Components
Troubleshooting
EPA & Safety
100
  • What is refrigeration?


  • The process of removing heat from a space


100
  • What is ohms?


  • Unit of electrical resistance


100
  • What is a metering device?


  • Meters refrigerant into evaporator


100
  • What is low airflow?



  • Frost on evaporator coil could indicate this airflow issue


100
  • What is the EPA? 

Environmental Protection Agency

200

Where is low pressure super heated vapor found on the refrigeration cycle

in the suction line going to the compressor

200
  • What is a multimeter?


a Tool used to measure volts, ohms, and amperages along with more measurements 

200
  • What is a receiver?


  • Stores and supplies refrigerant to the system


200
  • What does a dirty condenser coil Cause?


High head pressure, High amp draws, and possible compressor overheating on overload.

200

What does an EPA 608 Universal Certificate Cover in terms of applications?

Small appliances, Low, medium, and high temp applications.

300

What are all the things a condenser does?

Rejects heat, de-super heats, condenses (change of state from vapor to liquid), and Sub cools.

300
  • What is Ohm’s Law? and what do the letters stand for (E,I,R)?

The relationship between Volts, Ohms, and Amperes. E= Voltage (Electromotive Force, I= Amperage (intensity), and R= Resistance (ohms)

300

What does a compressor do and what is it?

Moves Refrigerant throughout the system, Increases a low temperature superheated vapor to a high pressure super heated vapor, Heart of the system and it's a vapor pump.

300

What would be an Indication or a way of checking Valves in a compressor?

By doing a bench test and front seating the suction line service valve, then manually running compressor until t pulls in a vacuum. wait several minutes to ensure pressure does not rise if it does this is due to bad reed valves in the compressor.

300

what is passive recovery?

passive recovery is relying on the pressure of the system to push the refrigerant out into a non pressurized container (A BAG!)

400

How do you calculate the Compression Ratio of a system?

add atmospheric pressure to both low and high sides pressures of the system (+14.7 psi) the divide the high side b the low side absolute pressure.

400

what is the wattage of a unit pulling 40 amps at 240V?

What is the btu?

9,600 watts

32,755 btus

400

What device absorbs heat from the conditioned space?

Evaporator

400

What would high super heat and low subcooling most likely be attributed to?

Low Charge

400

what is the leak rate for comfort cooling, commercial refrigeration and Industrial process refrigeration?

Comfort cooling = 10%

Commercial refrigeration = 20%

Industrial Process Refrigeration = 30%  

500

What is the formula for subcooling?

High side saturation temperature - Liquid line temperature

500

What are the two types of External relays used in commercial refrigeration?

Current relay and Potential relay

500

on a Defrost clock what connection is for defrost termination? what terminals control Freeze? and what terminals control Defrost?

Defrost termination = X

Freeze = 2-4

defrost = 1-3

500

What would high super heat and High subcooling be an indication of?

a Restriction

500

Why is and HFO called a hydrofluoroolefin?

the double bond that holds the molecule together is called an olefin bond.