What does PSI stand for
pounds per square inch
name the system that routes from the tank to the pump to the control valve and to an actuator or returns back to tank.
open loop system
What are inside the tank to help with the settling of particles and aeriation
baffles
Name 4 types of pumps
piston, gear, vane, and gerotor
What does it mean if a pump, valve, or actuator is discolored either brown or orange or red
too much heat
What size gauge should be used to check pressures
1 1/2-2 times larger
name the system that goes from the tank to the pump to a control valve to a motor and returns back to the pump
closed loop
a tank that is open to atmospheric pressure is called
vented tank
Name 2 ways to prelube pumps after an install
105 grease, pressurizing the system
Hoses are marked for their pressure rating True/False
True
name the tool that can check rotational speed
photo tach
another name for a linear actuator with 2 lines connected to it
double acting cylinder
What are 2 ways to measure hydraulic fluid in a tank
sight glass and dip stick
pumps produce _________ not __________
flow not pressure
The smaller the micron on a filter means
smaller the particles allowed to pass through
Flow meters can be hooked up in either direction True/False
False
what is the common name for a rotary actuator that is reversable
bidirectional motor
In a pressurized reservoir what component allows you to relieve the pressure in the tank
breaker relief
A good example of a nonpositive displacement pump is
water pump
Component that stores energy for when the machine or pump is not able to produce flow
accumulator
Flow meters have limits and ratings on them for how much they handle. True/False
True
What is the name of the component that protects the system from overpressureing
pressure relief valve
What 3 purposes does the hydraulic tank have in a hydraulic system
allows the oil to cool, lets particles settle to the bottom, supplies oil
What is a pump that can vary their displacement called
variable displacement
what is an way to check for a component failure in a system
cut open a hydraulic filter