Magneto's
Magneto's EXT.
Spark Plugs
Starter/Generator
Starters(ext.)/Turbines
100

The Magneto will run Hot if the ignition switch is ___ and the "P-Lead" is _______.

Off and Disconnected

100

The angle of rotation between neutral and when the breaker points open is called?

E-Gap


100

What happens to the spark plug when the primary circuit is broken?

Fires/Sparks

100

What is the primary advantage of a pneumatic starter over and electric starter?

High power to weight ratio

100

What kind of ignition system is most commonly used?

capacitor discharge

200

In a magneto the "P-Lead" being grounded allows for the magneto to?

turn off

200

The Primary and Secondary Coil share a common what?

Ground

200

What does increasing the gap do to the spark plug?

decreases intensity and advances the spark

200

Oil levels and Drain plugs are included in what kind of starter system?

Pneumatic 

200

High heat and voltage in a turbine engine makes it less susceptible to?

Fouling

300

Why are the breaker points and capacitor wired in parallel?

Hasten the collapse of the magnetic field.

300

____ and ____ make up the distributor system in a magneto.

Rotor

Block

300

When the spark plug gap is increased to much what condition might happen?

Hard Starting

300

What must engage in a pneumatic starter, after starting has occurred?

clutch

300

The use of the Start/Stop switch will fix what condition?

Hung Start

400

What is a sign of Flash Over?

conductive carbon trail

400

What indicates a normal magneto in a ground check?

slight decrease in RPM

400

What determines the heat range of a spark plug?

ability to transfer heat to cylinder head.

400

the start of motor rotation is the point that the current is at it's _____.

Highest

400

Does the starter circuit have any protection devices?

NO

500

Name the 4 components that make up the magnetic system of a magneto?

- Magnet

- Coil

- Pole Shoe

- Pole Shoe Extensions

500

Why are Flexible Metal Conduits routed from the distributor used?

reduce the effect of high-frequency electromagnetic waves emanating from high-tension ignition cables.

500

Simply define the normal wear condition of a spark plug, and a rich mixture wear on a spark plug.

- slight corrosion and soot, but nothing caked.

- Caked with a heavy black soot

500

Starter Overspeed in a pneumatic starter is stopped by what electrical component?

flyweight cutout switch

500

the "under current relay" disconnects power from what 2 systems?

starter/generator and ignition systems

M
e
n
u