Radiographic Quality
Equipment
Generator, Circuit and Tube
Image Processing
Who Knows!!
100

This poor image quality is caused by too few x-ray photons hitting the image receptor.  

Quantum mottle

100

This type of equipment relies on excellent positioning skills and extensive knowledge of surface and internal anatomy because the part being radiographed must be accurately positioned over the ionization sensors.

Automatic Exposure Control (AEC)

100

The component used to absorb low energy x-rays leaving the tube

filtration

100

This is a graphical display of the pixel intensity distribution for a digital image

Histogram

100

This is the universal protocol for transmitting data in PACS and contains the patient's name, DOB, and type of study

DICOM

200

As you increase OID, this happens to contrast

Contrast increases

200

In this type of radiography the image receptor is an imaging plate made of photostimulable phosphors made of Barium Fluorohalide

Computed Radiography (CR)

200

This part of the circuit is also known as the variable transformer, its the source for selecting kVp, and provides for the variation of voltage flowing in the x-ray circuit and applied to the x-ray tube.

Autotransformer

200

The xray beam changes as it travels through the patient by a process called...

Attenuation

200

Higher energy x-ray beams have fewer _____ interactions than x-ray beams with lower energy

Photoelectric

300

This refers to the ability of the imaging modality to distinguish between small structures that are very close together

Spatial Resolution

300

When the FOV stays the same and the matrix size increases, what happen to pixel size?

Pixels get smaller

300

This allows electrons to flow in one direction only from cathode to anode

rectifier or diode 

300

This is the process of combining multiple radiographic images with overlapping fields of view to produce a single image

Stitching

300

This is a plan of action to ensure that a diagnostic x-ray facility will produce consistent, high-quality images with a minimum of exposure to patients and personnel

Quality Assurance

400

Improper alignment of this will result in shape distortion

Central ray, IR, and body part

400

This is used in digital radiography to provide feedback to the technologist regarding the proper radiographic techniques for a specific exam that achieves an optimal image

Exposure Index

400

The line focus principle expresses the relationship between...

The actual and effective focal spot

400

This function increases visibility and contrast of  small, high-contrast structures 

Edge Enhancement

400

This is a measure of the capacity of the system to pass its spatial resolution characteristics to the final image

Modular Transfer Function

500

A system that has a higher bit depth will have what affect on contrast resolution?

Higher Contrast Resolution

500

What is the main difference between indirect and direct conversion detectors in image production?

Direct conversion: 

          exit radiation straight to electrical charge

Indirect Conversion: 

            exit radiation  to light to electrical charge

500

The electricity provided to the radiology department operates at...

120 pulses/sec

500

This degrades image quality and can be produced by: hardware failure, operator error, and software errors

Image Artifacts

500

This component converts light to an electric signal 

Photodetector or photodiode