Connectivity
DC Anatomy
Space
Grab Bag
Power
100
What is the name of the room in the data centre where Cross Connects are implemented?
Meet Me Room
100
More heavy duty than Duracell or Energizer brands, the UPS is responsible for charging these.
Batteries
100
This is an additional layer of physical security made of metal fencing which surrounds a customer's cabinets
Cage
100
This data centre efficiency metric is calculated by dividing total facility energy by IT energy
PUE
100
Interxion buys energy from the utility and uses it to sell ___ to customers
Power
200
What is the Interxion SLA on Cross Connect installation time?
3 days
200
Which mechanical component has an internal cooling coil, which absorbs heat energy from the air and transfers it to a fluid?
CRAC or CRAH unit
200
Which of the following is one of the Interxion standard, Pan-European products for Space? Metered Power, 16A Cabinet, Shared Area Cage
Shared Area Cage
200
The best way for a customer to open a Hands & Eyes ticket isn't through the ECSC, but through this
Customer Portal
200
With Advanced power, both legs of the ___ are UPS-conditioned while with Standard only one leg is conditioned
Plugset
300
Installing a _____ means that the customer does not have to wait for installation of pre-cabling in order to buy Cross Connects
Pre-cabled patch panel
300
This device conditions utility power and provides ride-through while the generator starts, in the event of a utility failure.
UPS
300
How much space is allocated to a Cabinet, as a unit of sale, by default?
2.5 SQM
300
What is the range of temperatures in the ASHRAE 2011 Recommended range for Data Centre temperature, and which is also the temperature range in our Customer SLA?
18-27 degrees C
300
Which of these are standard products? 230V Three-phase, 400V Single-phase, 48V DC
48V DC
400
Which one of the following is a connectivity media type? Single Mode Fibre, ATA/SATA, X86
Single Mode Fibre
400
Cold air is blown from beneath this, into the cold aisle, for cooling of Customer ICT equipment.
Raised Floor or Floor panels
400
The height of a cabinet is expressed in terms of ___, or "RU" for short
Rack Units
400
What type of free cooling is used by Interxion?
Free air cooling
400
99.999% uptime leaves room for how much downtime annually? 53 seconds, 5.3 minutes, 53 minutes, 533 minutes
5.3 minutes
500
Of Ethernet, UTP/STP or Single-mode fibre which has the greatest transmission distance capability?
Single-mode fibre
500
What component divides the main utility feed into various branch circuits?
Main Distribution Panel
500
Private cages have this type of cage wall.
Solid Panel
500
Of Optical, Aspirating or Electrostatic, which is best at detecting fires before flames occur?
Aspirating
500
What is the name we give to the number which represents the degree to which the electrical load is pulling the current out of phase with the voltage
Power Factor