Safety Imperatives
Spec/ White Book
Deenergized vs Energized Guidance
Work Methods
Safety Manual
100

What are the five Safety Imperatives

What is Grounding, DO, PPE, Switching and Tagging, Pole Inspections.

100

How deep should a temp pole be buried in the ground?

 What is 4'?

100

Is the De energized vs energized matrix just for cars hitting poles, True or False?

What is False.

100

How many employees have to be on site working together for you to have a documented prejob brief?

What is 2

100
How many degrees are you required to survey around your vehicle before entering to identify and remove hazards?

What is 360

200

How many tags should be placed on a set of pole top reclosers if they are on HLT?

What is 2. 

200

What size fuse goes in a fault tamer barrel on an arrester station? 

What is 20?

200

Can you work a pole energized if it has been hit by a car and you cannot secure it with an approved means of support?

What is No?

200

What is the MAD of 480 volts

What is 1'1" or 13"

200

What is the MPH of sustained winds should you stop traveling, work and climbing?

What is 39

300

How many times should probe a pole while testing?

What is 16?

300

What is the spacing from the top of pole to the neutral spool on a single phase straight line pole? 

What is 96"

300

Who must you contact if a pole has been damaged, and you are deciding if you work the pole energized?

What is your supervisor?

300

How long does it take for oxidation to build up on a set of grounds after brushing? 

What is 20 mins?

300

What is the minimum class of traffic vest that should be worn while on jobsite if you are not directing traffic?

 what is Class 2

400

What six items of PPE is required for you to wear while working on a parallel service?

What is hard hat, rubber gloves, FR clothing, Face shield, boots that meet all requirements and safety glasses under your face shield. 

400

What is the maximum distance a temp pole can be from the company attachment point?

What is a 100'

400

Should we be using the de energized vs energized matrix on normal day to day pole change outs? 

What is Yes

400

After establishing three-way communication with the Designated Observer, you may remove your rubber gloves if you are working from a pole or bucket and remain how many feet outside of the reach or extended reach of energized primary and conductors?  Hint:  Once this footage is met you have to follow five other conditions as well.

What is five'

400

Traffic vest/rain gear apparel shall be visible at a minimum distance of how many feet? 

What is a 1000'
500

What is the minimum weight hammer that you can use to hammer test a pole with?

What is 3 pounds?

500
What is the minimum amount of grounding stations NESC requires per mile on a multi grounded system like ours?

What is 4. 

500

What are the four approved means of securement? 

1. Boom and winch line attached to pole.

2. Quick splint, verta pole

3. Guys

4. Setting new pole beside and securing

500

If the pole ground is run to the top of the pole, leave how many feet of the pole ground unstapled or unconnected at the bottom of the pole so there is no direct path from the top of the pole to the work handling the bottom of the pole. 

what is 15'

500

What does CESR stand for?

What is Cardinal Electrical Safety Rules?