This feature on the GH100 allows the user to set a timer for when the next ACT test is due to be run in the CVOR
Interval Timer
The speed that the GEM Hemochron 100 takes to perform an ACT+ test
~4 minutes
Medtronic discontinued new sales of this ACT testing instrument in 2022
ACT Plus
When the tile appears this color on the GEMweb Plus dashboard, it means the GEM Hemochron 100 instrument is locked
Red
The two types of VerifyNow cartridges
P2Y12 and Aspirin
Because of this technology, the GEM Hemochron 100 is half the speed of all competitive ACT instruments on the market today
RAPIDCount technology
The GH100 ACT+ cartridge is able to measure up to this number of IU/mL of heparin
6 IU/mL
While the GEM Hemochron 100 performs an ACT+ test in ~4 minutes, competitive instruments typically take this number of minutes to perform the same test
8 minutes
This number of GH100 instruments can be connected to a single GEMweb Plus server
Unlimited!
The 5 quality checks of iQM2
System, Sensor, Process Control Stability, Pattern Recognition, Intraspect
This button on the GEM Hemochron 100 allows the user to quickly realize the readiness of the instrument to perform a test
QC button
The GEM Hemochron can approximately be charged up to this number of times before needing a replacement battery
500
The number of days or weeks the i-STAT cartridge may be stored at room temperature
14 days / 2 weeks
The GEM Hemochron 100 may display up to this number of results on the GEMweb Live interface
15
The clinical indications of the ROTEM delta
CVOR, Liver, Trauma
This instrument feature allows to user to easily view a patient's previous ACT results
Quick patient access feature
The GH100 ACT-LR cartridge is able to measure up to this number of IU/mL of heparin
2.5 IU/mL
The warm up time of the Medtronic ACT Plus instrument and cartridge
10 min instrument + 180 sec per cartridge
This GEMweb Plus version is required, at a minimum, to connect the GEM Hemochron 100
Version 6.0
The 4 criteria needed to calculate eGFR
Age, Gender, Crea Result, Race
The ACT+ and ACR-LR on the GH100 use this type of reagent which meets currently clinical practice guidelines and are less affected by hypothermia and artifacts
Maximally Activated
The GEM Hemochron 100 may store this number of patient and QC records
10,000
The sample volume required for a Medtronic high range ACT test
800 ul
GEMweb Plus provides these two quality control reports for the GH100
1). Levey Jennings
2). EQC (Electronic Quality Control)
The parameter on the ROTEM sigma that is not offered on the ROTEM delta
A5