You must wash your hands up to your ______ before donning sterile gloves
What is, elbows.
This color lid cleaner should only be used for hard non-porous surfaces.
What is, Purple.
The Chemo clean room is a ______ pressure room.
What is, negative.
You must perform hand hygiene for ________ while watching the clock.
What is, 30 seconds
Purple lid cleaner must dwell for ____
What is, 2 minutes
If the pressure is not in range in any of the clean rooms, the correct remediation process is
What is, to place a ticket with plant ops, and leave a comment in Pharmacy Keeper detailing remediation steps taken. Report to leadership
All _____ must be removed prior to hand washing
What is, jewelry, make-up, eye lash extenders, electronic devices.
This color lid cleaner should be used to wipe down telephones, key boards, mouses.
What is, Red.
The NON CHEMO clean room is a ________ pressure room.
What is, positive
Hand washing includes underneath the fingernails using a _____
What is, nailpick
Red lid cleaner must dwell for _______.
What is, 3 minutes.
The CHEMO clean room pressure range is
What is, between -0.01 and -0.03
Fingernails can only be _____ inch in length
What is, 1/4.
Peridox is only used in these areas.
Where is, IV hoods.
The NON CHEMO clean room pressure must be at least
What is, 0.02