 A rough-in inspection of plumbing, mechanical, gas and electrical systems shall be made prior to?

covering or concealment 

R109.1.2

100

System components that might be subjected to pressure drops below atmospheric pressure during operation or shutdown shall be protected by a _________  ___________  ____________.

Vacuum-relief valve

M2301.2

100

Pressure at the oil supply inlet to an appliance to an appliance shall be no greater than ______

pounds per square inch (20.7 kPa). 

3

M2204.3

100

Tank abandonment and removal shall be in accordance with the __________   ____________

_____________.

International Fuel Gas Code

100

true or false the moon has earthquakes

true

They occur due to tidal stresses connected to the distance between the Earth and the moon.

200

True or False -Appliances shall be installed in a location subject to vehicle damage, except where the unit has been raised 18 inches as required by IRC M1307.3


False

m1307.1

200

Where the winter design temperature in Table R301.2(1) is below 60°F (16°C), every dwelling unit

shall be provided with ___________.

heating

R303.9


200

The floor furnace shall not be installed where a door can swing within ______ inches of the grille opening 

12

M1408.3

200

Access trap door no less than ______ inches by _______ inches shall be provided for access to a floor furnace

22,30

M1408.4

200

what is the longest a person has held their breath underwater

On March 27, 2021, Budimir Šobat of Croatia held his breath for a total of 24 minutes 37.36 seconds.

300

For Combustion Air the minimum dimension of air openings shall be not less that _____ inches

3 

G2407.6

300

) Floor furnace register shall be located no less than _______ below any projecting combustible materials

60

 M1408.3

300

Wall registers of floor furnaces shall be installed no less than ______ inches from the adjoining wall at inside corners

6

M1408.3

300

Exhaust Hoods Systems exceeding 400 Cubic Feet per minute (CFM) shall have a damper, and it shall be a ______ damper or an ______ operated damper that automatically opens when the exhaust system operates

Gravity or Electrically

M1503.4

300

true or false it is possible to hum while pinching your nose

false but glad to see some of you try it

400

Where piping is located outside of a framing member and is located less than 1 ¼ inches (38mm) from the nearest edge of the face of the framing member to which the membrane will be attached, the piping shall be protected by shield plates that cover the width and ______ of the piping.

Length 

P2603.2.1

400

The maximum design operating pressure for piping systems located inside buildings shall not exceed _____ pounds per square inch (PSI) gauge. NOT COUTNING EXCEPTIONS

5 pounds

G2413.6


400

True or False -Ducts serving range hoods shall be constructed of galvanized steel, stainless steel, flex or copper

False

M1503.2

400

Gas Pipe Fittings installed in concealed locations shall be limited to the following Types except for

Bushings

G2415.5


400

how many states did America have during WW2

48

500

The bottom of the vent terminal for a mechanical draft system shall be located no less than _____

inches above finished ground level.

12

M1804.2

500

Shield plates shall be placed on the finished face of framing members where there is less than ______ inches (32mm) between the duct and the finished face of the framing member

1-1/2

G2415.7.1

500

True or False -Sauna heaters shall be protected from accidental contact by persons with a guard of material having a high thermal conductivity

False 

M1902.1

500

True or False -Cooling coils shall not be located upstream from heat exchangers unless listed and labeled for such use.

True

M1411.2


500