660
M2203.6
When the air infiltration rate is _______ air exchanges per hour or less, the dwelling unit shall have a whole house mechanical ventilation system
4
Table M1507.3.3(2)
Sauna heaters shall be equipped with a thermostat that will limit temperature to not greater than______ degrees Fahrenheit.
194
M1902.4
What is the minimum area required for the level working space located at the front or service side of an appliance access?
30"X30"
M1305.1.3.1
How Long was the shortest War?
38 Mintues the angelo-zanzibar war 1896
Pursuant to the Mechanical Section of the International Building Code, which of the following does not require a permit?
Self-contained refrigeration system containing 10 pounds or less of refrigerant.
R105.2 Mechanical
What type of venting is needed for an oil-fired furnace
Type L
Table M1804.1
A partition or stud located in a non-load bearing wall shall not be notched or cut more than percent of the stud or partition depth.
40
R602.6
Vents for natural draft appliances shall terminate not less than ________ feet above the highest connected appliance outlet.
5
M1804.2.3
True or False identical twins share the same fingerprint
False
Under floor plenums ground surface of the space shall be covered with a moisture barrier having a minimum thickness of ______ mils
4
M1601.5.1
Bathrooms, water closet compartments, and other similar rooms shall be provided with aggregate glazing area in windows of not less than ______square feet, one half of which must be openable
3
R303.3
A connector entering a masonry chimney shall extend through, but not beyond the wall, and shall be flush with the inner face of the liner. True or False
Double jeopardy
True M1805.2
When the appliance is located in the attic and provided with an unobstructed passageway that is not less than 6 feet high and 22 Inches wide for the entire length, the passageway shall be not more than ____ feet in total length
20
M1305.1.3
1977
Fuel oil inlet pressure shall not exceed _______ ps
3
M2204.3
Hydronic piping systems shall be tested hydrostatically at a pressure of one and one half (1-1/2) times the maximum system design pressure, but not less than ______ psi
100
M2101.10
When drilling and notching the top plate more than 50% of the width of the plate, a galvanized metal tie not less than what _______ gage and 1 ½ wide.
16 gauge
R602.6.1
Chimney and vent connectors of single wall metal pipe for oil and solid fuel appliances shall have a minimum clearance between the vent connector and any combustible material of ___ inches.
6
M1803.3.1
What food never expires?
Honey
Natural ventilation for hydrogen refueling with two permanent openings shall have one upper opening entirely within ______________ inches of the ceiling of the garage and one opening entirely within _______ inches of the floor
12,12
M13074.1.1
Duct in the garage and duct penetrating the walls or ceilings separating the dwelling unit from the garage shall be constructed of what gage sheet metal
No. 26
R302.5.2
Appliance vent termination shall not be located where doors may swing within ________ inches horizontally of the vent terminals
12
M1804.4
22, 30
M1305.1.4
the Hill
Taumatawhakatangihangakoauauotamateaturipukakapikimaungahoronukupokaiwhenuakitanatahu
is located in what country
New Zealand