Interactive
G-Suits
Oxygen Systems
Identifying Parts
EAWS
100
Measure someone for an MBU-23/P and tell me what size mask they should wear.
13-1-6.7-3 CH 6 Page 6-16 Figure 6-11.
100
Modifying the calf on the Anti-G suit is only authorized on these sizes.
Medium and Large. (The small sizes do not have enough excess material to perform the procedure). 13-1-6.7-2 CH 4 Page 4-9 NOTE at top of page on left
100
In Aircraft Oxygen Systems, a low pressure regulator is defined as 0 to ___ psig and high pressure is defined as 0 to ____ psig. *** HINT: 13-1-6.4-3 ***
Low: 0-500 High: 0-1800. 13-1-6.4-3 Page 3-1 para 3-4.
100
On the HGU-68/P, what numbers are pointing to CEPs?
18, 19, 20.
100
A Class A mishap is defined as...
Material Loss 2 Million Dollars or more, fatal injury.
200
Replace the nylon cord on an SDU-39 Distress Marker Light. ***THE CORD IS MARKED ALREADY!***
13-1-6.7-4 CH 3 Page 3-20 Starting at letter g.
200
Defects in this system of the Anit-G suit shall cause replacement of the entire garment.
The bladder. 13-1-6.7-2 CH 4 Page 4-17 Para 4-24.
200
*** DOUBLE JEOPARDY ***
You should purge liquid oxygen system piping and equipment with this.
200
On the HGU-68/P, what number is pointing to the swivel assembly?
15.
200
*** DOUBLE JEOPARDY! ***
What type of engines do C2-A Aircraft use?
300
Verify that LT Adams (RA7772) has the correct TD's annotated on his AER.
No reference. Verify with NAT 01.
300
The Anit-G Suit is placed on the interval for inspection cycle.
180 Days 13-1-6.7-2 CH 4 Page 4-17 Para 4-26.
300
When sotring lox converters outside, the words LOX CONVERTER STORAGE should be displayed using this color reflective tape, and the words NO SMOKING WITHIN 50 FEET in this color reflective tape. The letters should be no less than this many inches high.
Green and red. 2 inches high. 13-1-6.4-3 CH 3 Page 3-10 Para 5.
300
On the MBU-23/P, using correct nomenclature, what is number 4 pointing to?
MC-3A Oxygen connector
300
What does AOA stand for?
Angle of Attack
400
Pull out a CMU-33/A and point out everything that has either an expiration date or removal due to HI-TIME. If they have a HI-TIME name the inspection interval.
LPU-21E/P (180 Day), Batteries (SDU-39, Sidewinder, Penlight), Water Tablets (Expire every 3 years), Radio (360 Day), SRU-42/P (720 Day), Items in SRU-31/P or A/P.
400
For the leak test, inflate the bladder to this psig.
5 psig. 13-1-6.7-2 CH 4 Page 4-18 Para 4-27 Number 2.
400
Aircraft oxygen systems should be purged during which circumstances?
When left open to the atmostphere, empty, or when contamination is suspected. 13-1-6.4-3 Page 3-12 Para 3-48.
400
In Figure 4-10, for the LOX Conveter,point to the upper probe terminals.
Check Answer Key.
400
What are the three types of QA Audits?
Special, Workcenter, and Program
500
Properly Perform a Pre-Op Inspection on the MRS-III.
19-1-270. CH 3 Page 3-8 Para 3-8.
500
During the leak test, the bladder shall not drop more than this many psig in this many seconds.
1.0 psig; 30 seconds. 13-1-6.7-2 CH 4 Page 4-18 Para 4-27 Number 3.
500
When purging a system you should pass the oil-free, heated nitrogen through the system at this level psig at a minimum of this temperature for this amount of time.
120 psig, 90 degrees, 30 minutes. 13-1-6.4-3 Page 3-12 Para c on right.
500
On the MRS-III, point to the Supply pressure gauge.
Check Answer Key
500
Describe a Class Bravo Fire.
Flammable Liquids.
M