100

Air Exchanges

 new air replacements

100

Autoclave

a device that generates heat and pressure to sterilize objects and instruments, and measures vessels

100

Compounded Sterile Preparation

 a medication prepared with aseptic technique in a sterile, cleanroom facility

100

Drop factor

the number of drops that an IV tubing delivers to provide 1 mL; nurses may use this number to calculate the IV flow rate when using certain types of primary IV tubing; also called drop set or drip set

100

Injection Port

- a connector on the IV tubing that allows the injection of IV fluid or medication other than that in the current IC bag to be infused into the patient’s vein

200

Anteroom

an ISO Class 8 room or area immediately before the buffer room in which hand washing, hygiene, and garbing, are done and supplies and ingredients are gathered between the pharmacy department and the cleanroom or buffer area

200

Auxiliary Clamp

side clamp used to completely stop the IV solution from flowing

200

Critical Site

the part of the syringe and/or need that is at risk for contamination by touch or airflow interruption

200

Epidemic

 a regional widespread contagious disease

200

In-Line Filter

a device used in the IV line to remove contaminants such as glass, fibers, bits of rubber, and bacteria from IV fluids.

300

Asepsis

 the absence of pathogenic micro-organisms

300

Bacterium

a small, single-celled micro-organism that can exist in three main forms, depending on type: spherical (i.e, cocci), rod-shaped (i.e., bacilli), and spiral (i.e., spirochetes)

300

Disinfectant

 a chemical agent such as sterile 70% IPA used on inanimate surfaces and objects to destroy fungi, viruses, and bacteria, but not necessarily their sponges

300

Filtration

funneling of a liquid or gas through filters, or mesh screens with minute holes too small for biological and chemical contaminants to pass through

300

ISO

(International Organization for Standardization) an air quality classification from the ISO measures the amount of particulate matter in room air; the lower the ISO number, the less particulate matter is present in the air

400

Aseptic hand washing

a more aggressive soap and water hand washing procedure, followed by use of an antiseptic agent before donning sterile attire

400

Buffer room

 an ISO Class 7 or cleaner area where the PECs are physically located; also called the IV or cleanroom

400

Distillation

the process of boiling a liquid and capturing the condensed gases or vapor back into a purified liquid form

400

HEPA

 (high-efficiency particulate airflow) a device used to filter over 99% of particulate matter from the air to establish an aseptic environment in which to prepare CSPs

400

IV administration set

 a sterile, disposable device of many components (including the tubing and ports) used to deliver IV fluids to patients

500

Aseptic technique

the manipulation of sterile products and devices to avoid contamination by disease-causing organisms; includes cleanroom protocols and hand-washing and gowning procedures

500

Clean room

 an ISO-classified room ( or two-room configuration of a cleanroom area) in which the concentration of airborne particles is controlled to meet a specified airborne-particulate cleanliness class to prevent particle and microbial contamination of CSPs; also called the IV room or buffer room

500

Drip chamber

the small, open space just below the spike adaptor where the nurse counts the drops of fluid from the IV bag into the tubing to determine the flow rate of the IV solution

500

Horizontal Laminar Air Flow Workbench

(H-LAFW) also known as a laminar hood, a PEC (with an ISO Class 5 air quality in its DCA) used to prepare IV drug admixtures, nutrition solutions, and other parenteral products aseptically

500

IVPB

(IV piggyback) a small-volume parenteral (SVP) infusion (50 ml, 100 ml, 250 ml) containing medications attached to a primary LVP IV solution