Theoretical Maximum Specific Gravity
Ignition Oven
Gradation
AC by nuclear method
100

What is this test commonly referred to as?

What is the symbol used for this test?

And what is the value used in?

RICE

Gmm


Used in calculation for % compaction of HMA cores and % air voids of lab compacted specimens

100

What does the ignition oven test determine and how?

% asphalt binder by burning away the binder

100

What does a gradation determine?

particle size distribution of fine and coarse aggregate.

100

Difference between this method and an ignition furnace?

rapid determination of AC (% binder)

200

Describe the flask calibration.

Done monthly

Fill with water 77 +/- 1 F 

Completely full, cover plate, no air bubbles, dry exterior

average of last 3 weights= calibration weight

200

Describe the ignition furnace. Temperature, internal scale, data collection system, mass loss.


1000 F

internal scale 0.1g

internal computer- data collection- time, temp, %loss

Audible alarm when mass loss does not exceed 0.01 g for 3 minutes

200

What sieve should be over the #200?

#8 or #16

200

Where should this equipment be stored?

33 ft away from other radioactive sources

3 feet from hydrogenous materials and liquids

used in same location (ideally) 

New correlations and background measurements when equipment is moved

300

Removed entrapped air, what should the manometer read? 

How long should the sample be shaken for?

28 +/- 2 mm Mercury (Hg)

15 +/- 2 minutes


300

Describe the testing procedure and calculation

Record sample basket weight, basket and sample weight. Enter sample weight into oven. 

Remove when alarm sounds (no loss greater than 0.01%over 3 minutes)

weigh after 40 +/- 5 mintues

%AC=initial-final/initial x 100

300

How is the % passing #200 determined?

what are the results reported to?

B-C/B x 100

dry weight before wash-dry weight after wash/dry weight before wash x 100

0.1% unless results are 10% or greater

400

Your sample is done shaking, describe the rest of the procedure.

release vacuum slowly

fill with water 77 +/- 1 F

place in water bath at same temp and let stabilize or up to 10 minutes

place cover and record weight

400

Verify that total weight on furnace scale is within how many grams of the external scale?

+/- 5 grams

400

What are the weights retained on the sieve measured to?

The total must be within what % of the beginning weight?

0.1 g

0.3%

400

How to determine correction factor

3 correlation points

optimum, -1.0, +1.0%

16 minute count



500

How do you calculate the RICE?

What should the 2 values be within?

how do you convert to pcf?

A/(A+D-E)

dry/(dry+calibration-flask, water, sample)\

within 0.011

multiply by 62.4


500

How many correction factor samples are made?

What do you report the percentages to?

How to calculate correction factor? and what must the samples be within of each other

2 lab mixed, 1 blank (aggregate only)

0.01%

difference between 2 samples. must be within 0.15 of each other

500

How to calculate % retained on a sieve and % passing on a sieve?

What is % passing reported to?

% retained= sieve weight/dry weight x 100

% passing= 100- %retained

Report % passing to nearest whole number, but #200 reported to the nearest 0.1%

500

what is the dry aggregate count  and procedure?

establish a baseline, determine whether changes in agg properties are affecting AC results

dry at 300 +/- 15 f

fill pan 1/2 way, drop from 1" x4

Overfill, drop from 1" x4

strike off using sawing motion

record weight, and temp, run 16-min baseline