PriTech, Coal Tar, Rock Shield, Black Mastic, Paint?

What are WG approved coatings.

100

Maintain a minimum of 3' from sources of ignition or 120-degree heat


What are inside meter clearances?



100

Vent terminations shall allow gas to vent freely away from _______, _______, __________ or _________?

Building openings, windows, doors or Air Intakes.

100

What is the pipes material designation code?

PE2406/2708

100

This pipe is exposed to more soil & contaminants, causing corrosion?


What is Bare Steel?



200

Disbanded coating, holidays, contact with underground utilities?

What is an AOC?

200

A minimum of 6' from edge of roof

What is rooftop clearance, without protection?

200

Guards may consist of __________, ________, ______, etc?


Posts, Bollards, Railings 



200

What does NR on the pipe stand for?

No Rework - The pipe was not ground or pelletized & Reused.

200

What are different types of pipe found in the WG system?

Cast Iron

Bare Steel

Coated Steel

Polyethylene (PE or Plastic)

300

Use methods that does not damage pipe

What are procedures for removal of coating?

300

Controls the delivery pressure

What is a Regulator?

300

What is Not an SOS _____, _______, _______, ________, _________________?


Car port, Shed, Porches, Decks & Services & risers originally installed through foundation (older homes with indoor meters)



300

Why is weak link used?

Helps ensure the pipe is not stressed beyond limits

300

This is applied by spraying. What type of coating am I?


Liquid Epoxy Coating.



400

Corrosion, Pipe damage, damage coating & pipeline separation

What is exposed piping inspection?

400

Automatically shut off the flow of gas if regulator fails

What is an Security shutoff valve?

400

Rapid meter dial movement may indicate that the ___ is flowing rapidly or a major ____________ is downstream of the meter?

Gas, Major Leak

400

Gas pipe must be protected from heat _____ or greater


120 degrees



400

What should you do if you come across damage pipe during an installation?

(Hint) Three step process?

Stop the installation

Evaluate the damage

Contact the appropriate WG personnel

500

When done pipe should have a silvery, rough surface?


What is grit blasting?



500

Damages to facilities installed outside or inside of structures due to component failure, 3rd party damage, natural disasters or human error

What is a Hazardous Condition?

500

If there is No Immediate Hazard. What should you do?

Schedule it for repairs.

500

Damaged pipe is ______


Cut out, 3 pipe diameters



500

What damages are caused by machines or tools?


Coating defects

Weld defects

Mechanical damage