HVAC 1
HVAC 2
HVAC 3
HVAC 4
You Prolly Wont Know
100

True of False?

The Condenser is always operating in both Cooling & Heating mode

False

100

The Line that is always going to be warm to the touch is called?

The Discharge Line (3/8ths)

100

The Compressor is Located where in a Household?

The Condenser (Outdoor Unit)

100

The 3/4 (Bigger) Line is called?

The Sunction Line

100

True or False

The Condensers jobs is the same when it is a heat pump

False

200

What Separates the High side from the Low side?

The Metering Device

200

The Orange wire on a thermostat is what?

The Reversing Valve Solenoid 
200
Explain what the difference of a 80/20 Gas furnace is to a 90/10 Gas furnace

80% of the Heat goes into the house and the other 20% goes out the house. 90% is more efficient but more costly for obvious reasons

200

Name both fans in the Refrigeration Cycle

Condenser Fan Motor

Evaperater Fan Motor

200

Would are the effects of the Evaporator Coil if too much refrigerant is inside the system?

It Could Freeze

300

True or False?

The transformer steps down from 240v - 24v

False.. 120v - 24v

300

True or False?

The Evaporator gets both Hot air & Cold air blown through it

True.

300

True or False?

There is only one run of thermostat wiring involved in communicating from Heat to Cool

False.

300

The Evaporator produces...

Condensation

300

The Device that closes Voltage after a call for cooling is what?

The Contactor

400

What is the main effect of the Compressor if not properly charged?

Compressor can overheat

400
What do you measure on your Voltmeter for a bad Capacitor? 

Mircofarads 

400

How much gas pressure are you suppose to get going thru the Gas Regulator ?

7

400

The Place where the fire starts inside the furnace is called what?

The Ignitor Assembly 

400

How Many Microns are you suppose to get before you complete a Vacuum?

500 Microns

500

What are the 3 Terminal Names on the Compressor?

Common / Start / Run

500

What term is used when all lights shut off at the same time?

Wired in Series

500

How much Gas pressure are you suppose to get from the Regulator to the Gas Valve?

3.5

500

What has to happen first before the Flame comes on & starts pushing hot air across the Evaporator coil?

Pressure Switch must Close & Send Signal to Gas valve that its okay to light

500

What is the FIRST thing you do when you go to a service call AFTER talking to the Customer?

Take a picture or Write Down the Model & Serial number off the Data name plate