A
B
C
D
E
100
name the 2 major vents
What is stack vent and vent stack
100
a B.S. intended to serve a mobile home shall be not less than ____"
What is 4
100
maximum FU's on a relief vent
What is 6
100
no more than how many shower heads shall be served by a single shower drain.
What is 6
100
Bubblers shall be installed only on which fixture
What is Drinking fountains
200
the size of every vent pipe shall conform to which table
What is 2.5.7.1
200
the piping between a cleanout fitting and the drainage system it serves shall not change direction by more than ____
What is 45 degrees
200
The 4 vents stated in 2.5.4.5 and the 3 stipulations
What is cv, acv, yv and orv. no more than 2 fixtures max 1.5 fu's each, double sanitary t and the section of the vent pipe that acts as a wet vent is not less than 2" in size.
200
the trap seal depth on fixtures draining to an acid waste system shall be a minimum of _____mm
What is 50
200
what kind of water must be used to test a potable water system
What is potable
300
one-way rodding for a 4" pipe
What is 15 m
300
the developed length of fixture outlet pipes shall not exceed _____ mm.
What is 1200
300
which vent does not have to extend above F.L.R. of every fixture that it serves before being connected to another vent pipe
What is wet vent
300
a _____ trap shall not be installed in a drainage system.
What is bell
300
if a manufacturer states that an air test is not recommended, a _____ test shall be performed
What is water
400
for a ball test, what is the size of the ball for a 3" pipe and the ball must not be able to _____
What is 50mm and float
400
discharge piping serving a macerating toilet system shall be not less than ___ " in size
What is 3/4"
400
the size of the soil and waste pipe acting as a relief vent shall conform to which 4 tables
What is 2.4.10.6.a, 2.4.10.6.b, 2.5.7.1. and 2.5.8.1.
400
which 2 sinks cannot have not have concealed overflows
What is dishwashing sink and food preparation sink
400
the minimum amount of fixtures required to have an additional circuit vent
What is 9
500
where the sump or tank receives sewage, it shall be water- and air-tight and _________
What is vented
500
an icebox with an 1 1/4" fixture outlet pipe has a hydraulic load of ____
What is 1 fu
500
back pressure means pressure _____ than the supply pressure.
What is higher
500
the temperature discharging into a ____ shall not exceed 49 degrees Celcius.
What is bathtub
500
write 11 vents on the board
What is bv, vs, sv, vh, FAI, rv, cont vent, cv, yv, orv, wv, iv, dv
M