910/ENGINES
920/HYDRAULICS
930/NEETS
CORROSION CONTROL
4790.2E APPENDIX E
100

INTAKE , COMPRESSION, POWER AND EXHAUST

WHAT IS AN ENGINE CYCLE

100

SUPPORT EQUIPMENT MINIMUM SAMPLING REQUIREMENTS

WHAT IS NAVY CLASS 3

100

A/M24T-17 POWER FACTOR

WHAT IS 0.8

100

RESULTS FROM A DIRECT CHEMICAL ATTACK ON A METAL SURFACE THAT PROCEEDS UNIFORMALY OVER THE ENTIRE EXPOSED SURFACE

WHAT IS UNIFORM SURFACE CORROSION

100

FAILS CHECK AND TEST

WHAT IS BCM5

200

IN THIS UNIT ENGINE LUBE OIL IS CIRCULATED THROUGH A FLUID TO AIR HEAT EXHANGER, WHICH PROVIDES ENGINE COOLING AT AN OPTIMUM OPERATING TEMPERATURE.

WHAT IS THE A/S32A-45 (MRTT)

200

AIR BLEEDING, RECIRCULATION CLEANING, PURIFYING, FLUSHING, AND PURGING

WHAT ARE DECONTAMINATION METHODS

200

REPLACED R-22 REFRIGERANT

WHAT IS R-410A

200

FED-STD-595, COLOR 17925

WHAT IS GLOSS WHITE PAINT

200

BROKEN, BURST RUPTURED, PUNCTURED, TORN, CUT

WHAT IS MAL CODE 070

300

HYDRAULIC FLUID USED IN THE A/S32A-32

WHAT IS MIL-PRF-17111

300

A/M27T-15 COMPONENT CLOSES WHEN PRESSURE DROPS BELOW 10+/- 2 PSI

WHAT IS THE BOOST PRESSURE SWITCH

300

PROVIDES 120 KVA, 115/200 VOLTS, 3 PHASE, 400HZ AC POWER

WHAT IS THE A/M26M-6

300

CAN BE USED TO TOUCH UP SMALL AREAS NO GREATER THAN 1-2 SQUARE FEET

WHAT IS A SEMPEN (A93) (TOUCH UP PEN)

300

USED FOR ACCEPTANCE, TRANSFER, AND CONDITIONAL. 

WHAT IS WORK UNIT CODE 030

400

UNIT REQUIRES 900 COLD CRANKING AMPS TO START ENGINE. 

WHAT IS A/M32A-48 (BUDDHA)

400

THE UNIT EMPLOYS A TIME DELAY TO OVERRIDE THE AUTO-SHUTDOWN FEATURE. THIS ALLOWS THE SYSTEM TO BUILD BOOST PRESSURE AND REACH ITS MINIMUM OPERATING PARAMETERS DURING STARTUP. 

WHAT IS THE A/M27T-15

400

AIR COOLED CONDENSER COILS PROVIDE A MEANS FOR CONDENSING THE HOT REFRIGERANT GAS FLOW FROM THE COMPRESSOR AND REJECTING THE REMOVED HEAT FROM THE LVAC

WHAT IS CONDENSERS

400

FREQUENTLY FOUND IN ALUMINIUM SHEET AROUND STEEL FASTENERS

WHAT IS EXFOLIATION

400

REPAIR NOT AUTHORIZED

WHAT IS BCM 1

500

WHEN SHIPPING ALONE THE MSU REQUIRES THIS ITEM TO PREVENT DAMAGE. (NOT ATTACHED TO A TRACTOR OR THE TRAILER)

WHAT ARE VIBRATION ISOLATORS

500

DESIGNED TO OPERATE IN THREE MAINTENANCE MODES: SELF CYCLE, MAKE -UP, AND THE OPERATION CYCLE. 

WHAT IS THE LIQUID COOLANT FILTRATION UNIT (LCFU)

500

1 TON OF COOLING CAPACITY IN BTU

WHAT IS 12,000 BTU

500

FAILURES COMMONLY CAUSED BY ELECTROLYTES CONTAINING CHLORIDE OR CHLORINE CONTAINING IONS (E.G. SEAWATER)

WHAT IS PITTING

500

OFF SHIFT HOURS

WHAT IS AWAITING MAINTENANCE CODE M4

M