heating system
fire warning
instrument procedure parameters and landing gear
cargo capacity
mil specs
100

fuel consumption

54 pph

100

engine fire bottles 

3

100

bank and climb

60 degrees and 100 kias

100

right lateral CG limit and left lateral CG limit

8.5 in and 13.5 in

100

engine oil

MIL-L-23699

200

shutdown temp for cooling air for vent fan, combustion air fan

49 degrees

200

flame detectors per engine and fire bottle automatic discharge force

3 and 10 Gs

200

landing gear ground speed and minimum turn altitude

40 kts and 200 ft

200

cable break strength and weight limit of the standard 48" pallet

3700 lbs

200

hydraulic oil

MIL-H-83282

300

heating capacity 

600,000 BTU

300

flame detectors in APP/heater compartment and scan for each detector

2 and 90 degrees

300

normal cruise and slow cruise

135 kias and 115 kias

300

maximum weight on wheels and design gross weight

69,750 lbs and 46,500 lbs

300

P2(grade 30 or 50 only)

MIL-L-21260

400

fuel supply

#2 left main

400

nitrogen charge per container

600 psi

400

sink rate, GW < 46,500 lbs and max tail skid strike and sink rate, GW 46,500 - 69,750 lbs

672 fpm and 360 fpm

400

utility hoist cable length and utility hoist capacity

245 ft and 600 lbs

400

gear box oil

DOD-PRF-85734

500

204 C overheat switch in plenum chamber APP EMER T handle activated

auto shutdown

500

monobromotriflouromethane

4.5 lbs

500

landing gear emergency blowdown bottle

2500-3150 psi

500

automatic release (AUTOMATIC MODE) and automatic release (TWO POINT FLIGHT)

525+-225 lbs and 200+-50 lbs

500

WTR (Grease)

MIL-PRF-81322G