The Crew that Compliments
Living La Vida Live Line
PIC Me
We are all Tools
Destination Transformation
100

Can work from an unsecured ladder at a height greater than 3 metres (10 feet).

What is two lineman?

100

Before any work is carried out on energized conductors or equipment, arrangements shall be made to obtain a This Permit. 

Unless you are:

Application or removal of hot taps. 

b Installation or removal of approved bolt-on stirrups to conductors #2 or larger, provided rule 803 is followed. 

c Application or removal of stick mounted ammeters.

What is a live line permit?

100

Blue with orange stripes, applied when working away from grounds.

What is a Grounding Blocking Tag?

100

Must be used when a worker could fall a vertical distance of 3 m (10 ft) or more, or at any height where a worker could fall into dangerous machinery, substances, or hazardous objects.

What is fall protection?

Bonus point for Chin Strap.

100

The size of copper leads used on a 50 Kva.

What is 2/0?

200

Can Work on low voltage (less than 750 volts) energized or de-energized conductors or equipment.

What is one lineman?

200

You must wait this amount time after experiencing lightning or thunder to continue your work.

What is 15 minutes?

200

All orange, used when working on level 1-4 equipment and owned by the PIC.

What is a Clearance Tag?

200

Live line tools and the Load Break are tested at this Interval.

What is every 2 years?

200

Resistance and Reactance must be within +/- 7.5%

What is Impedance?

300

Can Work on an underground electrical system. This includes operating elbows, exposed switching devices, and applying or removing Worker Protection Grounding/Bonding.

What is two lineman?

300

No work shall be done on these two high voltage conductors unless they are de-energized and grounded.

(will accept 1 answer) 

What is #6 copper High Voltage conductors or #4 ACSR High Voltage conductor?

300

Orange with white stripes, used on level 5 equipment and owned by the worker.

What is Self Protection Tag?

300

DAILY DOUBLE

Breaking Strength/Working Load Limit

This is used in rigging for specified uses.

What is Safety Factor?

General 5:1

People 10:1

Chains 4:1

300

E=IR

What is Ohm's Law?

400

Can Install or remove of approved bolt-on stirrups.

What is 2 lineman and a rescue person?

Note: Rule 803.2c 803.2c means that 3 crew members are required to install/connect a new transformer where no stirrup previously exists. 

400

When Live line pole setting with two PLTs, the third crew member is an apprentice at this ITA level.

What is level 2?

400

Blue with orange words, owned by the PIC, used when there is a foreign source of energization.

What is a Test and Work Tag?

400

Design Safety Factor= Breaking strength/ WLL

for Safety Equipment.

What is 10:1?

400

You must use this device before installing a transformer and when the fuse trips from unknown cause.

What is the Miller Quick Check?

500

Can remove a tree using a chainsaw when the wire is down and there is public access.

What is One Lineman?

500

Red and owned by a different operating authority.

What is a Guarantee of Isolation Tag?
500

A sling angle should never be less than this.

What is 30 degrees?

500
At 14.4kv we 10%.

At 7.2 kv we 20%.

What is Transformer Fusing?