BOILER
MAIN CONDENSER
MAIN ENGINE
BLR WTR/FEED WTR
Systems
100

V2MD

What is the classification of the Boiler?

100

To condense steam into condensate.

What is the purpose of the Main Condenser?

100

To transmit the thermal energy of the steam to mechanical energy to propel the ship through the water.

What is the purpose of the Main Engine?

100

What is the only water used in the boiler.

What is feed water?

100

A system that is used to create combustion in the boiler.

What is the Fuel System?

200

Tubes that direct feed water from the steam drum to the headers.

What are Downcomers?

200

The type of heat exchanger that the Main Condenser uses to condense steam.

What is crossflow?

200

Means to reduces the speed two times.

What is double reduction?

200

Used to remove excess chemicals from the feed water at all times while the boiler in online.

What is continuous blowdown? 

200

Used to lubricate the main engine bearings.

What is Lube Oil?

300

A big header that distributes water to the generating tubes.

What is the water drum?

300

The primary way to supply seawater to the main condenser when under 12 knots.

What is Main Circ Pump?

300

The orientation the gear teeth in a "V" pattern to reduce axial thrust.

What is Double helical?

300

The piece of equipment that produces feed water when underway.

What is the Evap?

300

Used as a cooling medium for the stern tube shaft seal.

What is sea water?

400

Located in the steam drum to remove water by a rapid change in direction.

What is the secondary separator (dry box)?

400

The heat sources of the main condenser.

What are Make up feed, Aux exhaust, and Fresh water drain collecting tank?

400

An instrument used to view the flow of lube oil in the main engine.

What are Sight Flow Indicators?

400

Is caused in the boiler when there is an unbalance of chemicals in the feed water.

What is corrosion?

400

The Emergency Feed Pump can be operated with 3 different systems.

What is 600 Aux, 150 Wet, and LP Air?

500

The tubes that protect the superheater tubes from direct radiant heat.

What are the screen wall tubes?

500

6574

What is the number of tubes in the main condenser?

500

An installed instrument used to determine the position of the HP and LP Turbine Rotors.

What are Rotor Position Indicators?

500

A chemical injected into the DFT to treat condensate.

What is EDTA?

500

The system that is supplied to batch treat the Lube Oil settling tanks.

What is 150 Wet?

M
e
n
u