Coliform Basics
Sampling & Monitorin
Disinfection
Storage Tanks & Maintenance
Cross-Connections & Backflow
100

This type of coliform bacteria is used as an indicator of environmental contamination.


Coliform Bacteria (total)

100

Coliform samples should be taken from representative sites, but never from this type of location.

dead ends, outside taps

100

This is the most commonly used disinfectant in drinking water systems.

Chlorine

100

This type of maintenance is performed before deterioration occurs.

Preventative

100

This term describes any physical connection that could allow contamination into a potable water system.

cross-connection

200

This specific bacteria indicates fecal contamination and has its own MCL.

Escherichia Coli

200

If a routine sample is total coliform–positive, repeat samples must be collected within this time frame.

24 Hours

200

This disinfection method provides no residual in the distribution system.

UV

200

Overflow pipes should end within this distance of the ground.

1 foot

200

This type of backflow occurs when system pressure drops and creates a siphon.

backsiphonage

300

A standard coliform sample bottle must hold this exact volume of water.

100 milliliters?

300

In case of a positive total coliform sample, one repeat sample must always be collected from this location.

original routine sample site

300

This disinfectant is formed when chlorine reacts with ammonia.

Chloramines

300

This tank component prevents vacuum conditions and must be screened to keep animals out.

Air vent

300

This backflow condition occurs when pressure on the customer side exceeds system pressure.

backpressure

400

Coliform sample results are reported by laboratories using these two possible outcomes.

present or absent?

400

Triggered Source Water Monitoring applies when a positive TCR sample occurs in this type of system.

groundwater system

400

This powerful disinfectant must be generated on-site and leaves no detectable residual.

Ozone

400

This corrosion protection method uses sacrificial anodes to protect steel tanks.

Cathodic Protection

400

This type of backflow prevention method provides a physical separation and is not testable.

air-gap

500

The original Total Coliform Rule was approved by Congress and enacted in this year.

1992

500

Coliform sampling results must be stored by the water system for at least this many years.

5 Years

500

This chlorine product is a greenish-yellow gas and is 2.5 times heavier than air.

Chlorine Gas

500

According to EPA guidance, the typical life expectancy of a water storage tank falls within this range.

30-60 Years

500

Backflow assemblies must be inspected and tested by individuals with this qualification.

certified cross-connection control testers