Which table is used to size conductors for ranges, ovens, and counter mounted cooktops
T220.55
What is a receptacle outlet with 2 duplex receptacles called
Quadruplex outlet
how many volt amps are allotted to a laundry circuit ?
1500VA
should you state your name when calling the supply house?
Yes
Definition of bonded
connected to establish electrical continuity and conductivity.
Overcurrent protection is required to be provided For each ungrounded conductor
240.20(A)
split-wired duplex receptacles usually have the always hot receptacle on the _____
Top
2 loads that do not con at the same time are known as?
Noncoincident loads
minimum size for a residential service
100 A
THWN can be dual rated and used at ___ degrees C in dry locations
90
Which table is used to size service conductors up to 400A
T310.12
outdoor receptacles may not be more than ____ ft above grade
6.5 ft
The standard method for calculating service size is found in? (Article and Part)
Article 220 part 3
Smoke alarms in basements Shall/shall not be connected to GFCI circuits
Shall not
Underground service conductors between a pad transformer and a meter
Service lateral conductors
Which code states that the rating of a branch circuit is based on the rating of the overcurrent device?
210.18
sound ratings on ballasts range ____ thru____, with____ being the quietest
A,F,A
The biggest motor in a residence is usually
The heat or A/C
Concrete encased grounding electrode
UFER ground
Service conductors min vertical clearance over railroad tracks
24.5 ft
Which article covers electric vehicle power transfer systems?
Article 625
What‘s the minimum clearance for surface mounted fluorescent luminaires in closets?
6in from storage space
What is the Volt Amp allowance for a 4000w Water heater, 3x 5A Fart fans, a 17A dishwasher and an 8.47 disposer?
6636 VA
What is the general lighting and receptacle load for a 24'x 30‘ 2 story house with 2 small appliance and one laundry circuit?
4029 VA
Residential transformers are typically, a ____-____configuration
Delta-Wye