Lets Talk Dirty
Tools in SPD
Define This
Rules to Follow
SPD101
Final Jeopardy:
CHEMICAL DISINFECTANTS
200

Decon has what type of air pressure:

Negative

200

Instruments that have a shiny surface

Mirror finish

200

The process or ability to kill or control the growth of living organisms is called this:

Biocidal

200

Always check the insulation coating for nicks & cuts on these instruments:

What is a Laparoscopic Forcep?

200

Organization that issues regulations to ensure medical devices are safe:

FDA

200

One Disinfectant that is part of the Halogen Family:

What is Chlorine or Iodophors?

300

Left over residue on instruments:

Bioburden or Biofilm

300

Used during joint scope surgery:

Arthroscopy instruments

300

Term for the lining of the uterus:

Endometrium

300

These rigid container parts should always be removed from the lid & cleaned separately:

Retention plates

300

This provides a "grocery list" to pull Case Carts for daily surgical cases:

What is a Pick Sheet/List or Doctors Preference Card?

300

 

400

The third sink in a three bay sink system is for rinsing with this type of water:

What is Critical water?

400

Leak Testing is performed as a first step for these types of scopes:

What are Flexible Endoscopes?

400

The medical term/suffix meaning "to Suture":

What is -rrhaphy?

400

The book says this material is NOT an acceptable sterilization packaging:

Canvas 

400

Robotic instruments contain these:

What are Wires/Cables?

500

QUATS are this level of chemical disinfection:

What is Low/LLD?

500

Hoses that should be pressurized for proper inspection, usually dark in color:

Pneumatic Hoses

500

>>R.O.<< Critical Water stands for:

What is Reverse Osmosis?

500

These outline healthcare minimum levels of quality and safety, "Laws & Best Practices":

Regulations & Standards

500

SPD workers should NEVER place this type of pack inside of an instrument set for sterilization:

What is a peel pack?

600

What does LCS disinfection stand for:

Liquid Chemical Sterilant

600

Steam sterilizer wrapping material that is already double layered is also known as this term: (HINT: Not Sequential)

What is Simultaneous?

600

These types of muscles are consciously controlled and move only when we want them to:

Skeletal muscles

600

ANSI/AAMI ST91:2021 States, "that HLD is the minimum biocidal requirements for ___________":

What are Endoscopes?

600

Devices categorized as Semi-Critical must at least undergo ___________ prior to use:

What is HLD?