A group of fixtures consisting of a water closet, lavatory, bathtub or shower, including or excluding a bidet, an emergency floor drain or both.
What is a Bathroom Group
100
A water closet, lav, urinal or bidet shall not be set any closer than this measurement from its center to any side wall partition, vanity or any other obstruction.
What is 15 inches.
100
Water heaters and storage tanks shall be provide with this to allow observation, maintenance, service and replacement.
What is ACCESS.
100
The material that is allowed by code for above ground drainage and vent piping would be found in this chapter.
What is Chapter 7.
100
This is the minimum size vent allowed by this code.
What is 11/4
200
That part of the lowest piping of a drainage system that receives the discharge from soil, waste and other drainage pipes inside and extends 30 inches in developed length beyond the exterior of the building.
What is the Building Drain.
200
Shower waste outlets shall not be any less than this.
What is 1 1/2.
200
The cold water branch line serving a hot water storage tank or water heater shall be provided with this.
What is a Valve.
200
A chemical waste system shall be completely _______from the sanitary drainage system.
What is Separate.
200
This method allows you to vent any combination of fixtures within two bathroom groups.
What is a Wet Vent.
300
A general term for any vertical line of soil, waste, vent, or inside conductor piping that extends through at least one story with or without offsets.
What is a Stack
300
Lavatories shall not have a waste outlet not less than this.
What is 1 1/4.
300
The relief discharge piping from a hot water storage tank or water heater shall discharge not more than how many inches from the floor.
What is 4 inches.
300
This will be needed at every change of direction greater than 45 degrees in the installation of building sewer, building drain, and horizontal waste or soil lines.
What is a Clean out.
300
There are no offsets allowed in this stack.
What is a Waste Stack Vent.
400
Water free of impurities. Meets the quality requirements of the Public Health Service Drinking Water Standards.
What is Potable Water
400
The waste outlet on this fixture is a minimum of 2 inch.
What is a Floor Drain
400
A water temperature of 85 to 110.
What is Tempered Water.
400
This chart does not include branches of the building drain.
What is 710.1(2)
400
In this method the upper fixture shall not be a water closet.
What is a Common vent.
500
A person appointed and employed by a governmental subdivision charged with the administration and enforcement of the state code or codes.
What is Code Official.
500
A waste outlet shall not be required on these two fixtures.
What is an Emergency shower or Eyewash stations.
500
The developed length of hot or tempered water shall not exceed this measurement, without a recirculating loop or heat trace added to the system.
What is 50 feet.
500
Drainage fixture units values for continuous and semi continuous flow into a drainage system shall be computed on the basis that 1 gpm of flow is equivalent to how many fixture units.
What is 2.
500
Only this number of fixtures shall discharge upstream of the dry-vented fixture drain connection in a wet vented system.