Sanitary DRAINAGE
INSPECTIONS
FIXTURES
WATER SUPPLY
VENTS
100
The size of a branch or stack depends on the ______ load on the system.
What is DFU
100
The Michigan Plumbing Code is based on the ____________Plumbing Code
What is THE INTERNATIONAL
100
Fixtures are found in this chapter.
What is CHAPTER 4
100
The water service pipe and the building sewer SHALL be separated by not less than ______ft. of undisturbed or compacted earth.
What is 5
100
In this method the upper fixture SHALL not be a water closet.
What is INDIVIDUAL AS COMMON or COMMON
200
The minimum size fixture branch for a water closet.
What is 3 INCH.
200
You may get a stop work order if you fail to do this
What is APPLY FOR A PERMIT
200
Bolts for water closets SHALL be made of_______.
What is BRASS
200
If the water pressure is _______psi or greater you need a water pressure reducing valve or regulator.
What is 80
200
The smallest diameter vent allowed by the Michigan plumbing code.
What is 1 1/4
300
You SHALL never lay this fitting on its side, regardless of size.
What is a SANITARY TEE
300
A permit is good for this many days
What is 180 days.
300
A water closet, urinal, lavatory or bidet SHALL not be set any closer than ________inches from its center to any side wall or partition.
What is 15
300
____________ SHALL have ______ water service pipes in case one is interrupted.
What is HOSPITAL , and 2
300
This method can vent two to eight fixtures.
What is CIRCUIT VENT
400
2 inch or smaller, you may lay this fitting on its side.
What is A 90, SHORT SWEEP QUARTER BEND OR QUARTER BEND.
400
The water supply system test shall be not less than____psi holding for no less than______minutes.
What is 50 & 15.
400
The trap or stand pipe for an automatic clothes washer shall not be less than this in diameter.
What is 2 INCHES.
400
The correct Backflow device depends on the application and ______ of Hazard to the potable water.
What is DEGREE
400
How many DFU'S are allowed on the circuit vent ?
What is 0,
500
You may use this fitting for back to back water closets, only if the center of the water closet and the connection to this fitting is _______ inches or greater.
What is a DOUBLE SANITARY TEE, 18 inches.
500
If your hangers are farther apart than this measurement, on pvc pipe, you may get a correction notice.
What is 4 FT.
500
The stand pipe for an automatic clothes washer SHALL connect to a _______ inch or larger fixture branch or stack
What is 3
500
Vacuum Breakers SHALL not be installed less than _____ above the flood level rim of the fixture.
What is 6 INCHES.
500
an 1 1/4 trap can be this far from its vent
What is 8 ft.
M
e
n
u