House Keeping
SOPs / Training
Processes / Methodology
cGMP / GDP
Safety
100

How is the lab cleaned? How do you make VIREX?

Virex bench tops and hoods

IPA Hoods

VIREX 1mL per 256mL water.

100

Where do you find your SOPs? 

R://

QA Control View Only

Current SOPs


100

How do you properly serial dilute from a 1:10 initial dilution.

1mL into 9mL

or

10mL into 90mL

100

What is the proper format for dates

mm/dd/yy

100

Evacuation location for Fire?

Back of the building by the dumpsters

200

What is the proper location for biohazardous materials?

Autoclavable designated area on benchtop

Nonautoclavable designated biohazard bin

200

What SOP would you find cleaning procedures?

700M0120

200

Name the color tape and corresponding day

M-Yellow

T- Orange

W-Red

TH- Blue

FRI-Purple

SAT- White

SUN- Green

200

What is the proper way to correct an error?

Single cross out line, describe reason for correction, initial and date.

200

Name Proper PPE standards

Safety Glasses

Lab Coat

Hair/ beard net

closed toed shoes

appropriate cuff length gloves

300
How do you know your equipment is validated for use?

All equipment is tagged by QA department. There are calibrations/ verifications that are conducted to ensure working conditions are met before testing.

i.e., daily balance verification

300

How do you know if you are qualified to perform the method?

Training Matrix- broken into Families each method should be assigned to a family.

300

How do you assign expiration date to prepoured plates

30 days from pouring unless expiration on label comes before.

300

When conducting testing at what point in the procedure should you document your weight?

at time of weighing. 

300

On the weekends- what is the proper procedure for being in the building

Personnel is to sign in using the weekend log in the front lobby

400

Where should all pending QC media be stored?

In Media or Pending QC area in Lab.

400

What SOP relates to EM and what is the purpose?

700M0100- monitor the environmnetal conditions in the lab to ensure there is not heavy microbial activity that could impact the testing.

400

What is the purpose of an in process air plate? 

to monitor the environment inside the BSC during testing

400

What is the purpose of documenting everything that happens during a test?

Provide the client with accurate results and maintain data integrity.

If you didn't document it- it didn't happen.

400

When performing a new task what can you do to make sure you are being safe?

perform 2 min for my safety- MAIA app

500

How do you perform deep cleaning procedures? How often is this done?

Hoods are taken a part and cleaning thoroughly with VIREX and IPA.

Drawers are emptied and cleaned with Virex and IPA

Quarterly

500

How do we deem media acceptable for use?

Every batch of media goes through a QC process 

500

What ISO accreditation are we trying to receive?

ISO 17025 is the international standard that sets out the general requirements for the competence, impartiality, and consistent operation of testing and calibration laboratories. Most labs must hold accreditation to this standard in order to be deemed technically competent

500

What does ALCOA stand for?

Attributable

Legible

Contemporaneous

Original

Accurate

500

If you feel unsafe, what can you do?

STOP WORK Authority

M